PCBRM15 & PCBRM System 5.2 User’s Manual Chapter 3: Set Up & Installation Part No. 4005.00.906 3-6 6. Loosen the rear two screws of each arm _ turn. 7. Turn the adjustment screw clockwise on both arms equally an …

100%1 / 120
PCBRM15 & PCBRM System 5.2 User’s Manual Chapter 3: Set Up & Installation
Part No. 4005.00.906 3-5
3. Place the board to be used in the process in to the
carrier arms. Align the site to be processed on the
board over the flow well and lock in place.
4. The board now will need to be leveled to match the
flow well. (step 2)
NOTE: The adjustment will be in the Y-axis only
not the X-axis
5. To adjust the board to match the flow well, loosen
the two front screws only on each arm two turns.
PCBRM15 & PCBRM System 5.2 User’s Manual Chapter 3: Set Up & Installation
Part No. 4005.00.906 3-6
6. Loosen the rear two screws of each arm _ turn.
7. Turn the adjustment screw clockwise on both arms
equally an 1/8 of a turn at a time until the level is at
the desired place.
8. Once level is achieved, bring the rear two screws
to bare only. Make a final adjustment as required
and bring the front screws to bare. Now snug up all
the screws – Do Not Over tighten.
PCBRM15 & PCBRM System 5.2 User’s Manual Chapter 3: Set Up & Installation
Part No. 4005.00.906 3-7
Compliant
(carrier) Arm
Lock Assembly
Carrier Arm
3.3 PCBRM System 5.2 - Carrier Arms Installation
Loosen lock knob so compliant (carrier) arm lock assembly can straddle the x-axis rail.
Place compliant arm lock assembly in place, as shown.
Use mounting screws to mount carrier arm to bearing block.
Lock Knob
Bearing
Block
Mounting
Screw
X-Axis
Rail