00195166-0402_SM_D4_EN.pdf - 第112页
Service Work Component Handling Cutter 112 Serv ice Manual SIPLACE D4 4.3.2.12 Exchanging the Empty-T ape Duct Assembly See also: J 6.4.3 Check the gap between the empty-tape baffle, in side and the leading edge of the t…

Service Work
Cutter Component Handling
Service Manual SIPLACE D4
111
Installing the Proximity Switch
See also:
J
Tightening Torques for Cutter Screws [
J
87]
J
4.3.2.14 Final Steps [
J
114]
X Install the new proximity switch precisely in the
position you marked on the short-stroke
cylinder with the permanent marker.
Tighten the screws to the correct torque.
X Run the cable in the cable duct and establish
the press-fit connection to the control board
with correct allocation to the proximity switch
left/right and front/back (for allocation see
diagram above).
Push the excess lengths of cable into the
cable duct.
X Use a cable tie to fasten the cables running to
the cable duct to the fixing pedestal on the
control board box.
Make sure the cables/press-fit connections
are not subject to strain (8).
X Refit the cover (9) on the control board.
X Install the cover on the cable duct (5).
X Perform the "Final Steps" including the
substep "Load the SITEST program and
initiate the cutting strokes".

Service Work
Component Handling Cutter
112 Service Manual SIPLACE D4
4.3.2.12 Exchanging the Empty-Tape Duct Assembly
See also:
J
6.4.3 Check the gap between the empty-tape baffle, inside and the leading edge of the tape deflector.
[
J
241]
J
Tightening Torques for Cutter Screws [
J
87]
WARNING:
There is a high risk of injury from the blades and the tape deflector.
Never reach into the cutter from below or into the empty-tape duct from above.
X Turn the machine and then the flow of
compressed air ON.
X Disconnect the movable changeover table
from the machine and move it out of the
machine.
X Turn the machine OFF, disconnect the
machine from the line and turn off the flow of
compressed air at the compressed air. Actuate
the needle valve on the compressed air unit to
bleed the compressed air lines (see DANGER
text in ).
X Loosen the screws fastening the empty-tape
duct assembly (11, 9).
X Loosen the screws fastening the nozzle
changer, lift it up somewhat and hold it in this
position.
X Carefully put the nozzle changer down.
X If you only want to exchange the faulty baffle
inside/outside and/or the reject box, proceed
as indicated in section (4.3.2.13 Exchanging
Baffles and / or Reject Box (Profile)
J
113 ) .
X Screw the new "empty-tape duct assembly"
onto the machine base (2 M4 x 16 screws
each on the left and right).
-> Tighten the screws to the correct torque.
X Check the gap between the empty-tape baffle,
inside and the leading edge of the tape
deflector.

Service Work
Cutter Component Handling
Service Manual SIPLACE D4
113
4.3.2.13 Exchanging Baffles and / or Reject Box (Profile)
See also:
J
4.3.2.14 Final Steps [
J
114]
J
6.4.3 Check the gap between the empty-tape baffle, inside and the leading edge of the tape deflector.
[
J
241]
X Remove the "empty-tape duct assembly".(See
section (4.3.2.12 Exchanging the Empty-Tape
Duct Assembly
J
112 ) .)
X Loosen the self-tapping M4 screws on the
baffle or reject container to be
dismantled (13 to 18).
X Insert the new baffle inside/outside and /or the
new reject container and fasten it with the self-
tapping screws (13 to 18).
X Fit the empty-tape duct assembly and check
the gap between the empty-tape baffle, inside
and the leading edge of the tape deflector.
X Perform the appropriate “Final Steps”.