00195166-0402_SM_D4_EN.pdf - 第184页

Service Work C&P12 Placement Head Replacing the Star [00341181] 184 Serv ice Manual SIPLACE D4 4.5.17.2 Replacing the Air Blast Supply to the S tar [030008 96-xx] Removal/Installation 4.5.17.3 Replacing the Silicone …

100%1 / 268
Service Work
Replacing the Star [00341181] C&P12 Placement Head
Service Manual SIPLACE D4
183
ATTENTION: The power pack operating time is limited!
The maximum operating time for the power pack of the star motor is five minutes. Do NOT
exceed this time If you have to disconnect the power pack from the power source because it has
been operating for five minutes, always insert the gauge pin before switching the power pack
back on again.
Legend
1. Star drive, digital/ DLM3
2. 4 x M5x16 hexagon socket-head screws
3. C&P head front part
X If you still can not fit the star in the magnetic
neutral position of the star motor, follow the
instructions below:
X Loosen the four M5x16 hexagon socket-head
screws (2) fixing the star drive (1) and turn the
star drive in the direction that will allow the star
to be adjusted with respect to the magnetic
neutral position.
X Tighten the four hexagon socket-head screws.
1
3
2
X Loosen the three M3x8 hexagon socket-head
screws (5) fixing the star again and repeat the
adjustment procedure.
NOTE:
The star is correctly installed, if it does
not turn out of position when the gauge
pin is removed during zero current star
operation.
X Remove the gauge for the star.
X Insert the power cable connector for the star
drive into the slot on the intermediate
distributor. The plug connector is an anti-
rotation connector.
X Fit the front part of the C&P head onto the back
part of the C&P head.
X Check the magnetic neutral position.
1
7
6
5
4
3
2
Service Work
C&P12 Placement Head Replacing the Star [00341181]
184 Service Manual SIPLACE D4
4.5.17.2 Replacing the Air Blast Supply to the Star [03000896-xx]
Removal/Installation
4.5.17.3 Replacing the Silicone Hoses on the Star [00341183S01]
Removal
NOTE: Do not remove the star!
For clarity, the diagram shows the star
when removed from the machine.
However, you do not need to remove
the star to replace the air blast supply.
X Undo and remove the two screws fastening
the air blast supply (1).
X Fasten the air blast supply with the two screws
provided.
X Dismantle the star from the C&P head.
X Remove the sleeve from the segment of the
defective hose.
X Undo and remove the two screws fastening
the air blast supply (1).
X Disconnect the hose (3) from the segment (1).
X Now pull the valve (2) out of the star.
ATTENTION: O-ring
There is an O ring behind the valve.
Make sure that you do not lose this and
that you fit it again during installation!
X Disconnect the hose from the valve.
Service Work
Replacing the Star [00341181] C&P12 Placement Head
Service Manual SIPLACE D4
185
Installation
X Installation is performed by following the above instructions in the reverse order. Observe the
following points:
Check that the white connection pieces are seated firmly on the segments. If these are loose, you
will need to replace the entire star.
Make sure that there is an even space between the hoses:
When fitting the star, make sure that the silicone hoses are not pinched and/or damaged.
ATTENTION:
If the connecting silicone hoses
between the valve and segment are
replaced, make sure that they are not
damaged by rubbing against one
another (2) .
X To ensure this, make sure that the
silicone hoses have been cut to the
exact length and that they are
pushed onto the respective
connection pieces as far as possible
(up to the stopper).
X Make sure that the hoses do not
touch (1) one another. Check the
distance while pushing all segments
all the way in. Ideally, the distances
should all be the same.