00195166-0402_SM_D4_EN.pdf - 第36页
Overview Component Handling Changeover T able 36 Serv ice Manual SIPLACE D4 3.4 Component Handling 3.4.1 Changeover T able 3.4.1.1 S tructure of Changeover T able (S T able) 3-20: Component trolley – front and back view …

Overview
Parts Overview Gantry
Service Manual SIPLACE D4
35
3-18: Gantry - parts overview 2
Legend
3-19: Gantry - parts overview 3
Legend
The compressed air distributor (2), gantry distributor (3) and hotlink card (4) are located under the
cover (1).
1 Elastomeric spring 25x10.5x50 (90 Shore A)
[00301040-01]
2 X axis scale [00329316-01]
3 Deflection unit X [00330938-02]
1 Cover 3 Gantry distributor
2 Compressed air distributor 4 Hotlink card

Overview
Component Handling Changeover Table
36 Service Manual SIPLACE D4
3.4 Component Handling
3.4.1 Changeover Table
3.4.1.1 Structure of Changeover Table (S Table)
3-20: Component trolley – front and back view
Legend
1. Movable base
2. Tape reels container
3. Handles
4. Tape waste container
5. Communication unit; the splice detection unit
option is fitted under the communication unit
6. Changeover table
7. Switch for lowering the changeover table
8. Pockets for the setup list printouts
9. Voltage 30 V communication unit (yellow LED)

Overview
Cutter Component Handling
Service Manual SIPLACE D4
37
3.4.2 Cutter
3.4.2.1 Safety Instructions
DANGER:
The safety instructions in the chapter "Operational Safety" in the operating manual and this
service manual take priority.
The machine is supplied with
219/380 V +/- 5% or
230/400 V +/- 5% or
239/415 V +/- 5% or
117/204 V +/- 5% or
133/230 V +/- 5%,
50/60 Hz mains voltage.
Inside the machine base this is true even while the master switch is turned off.
X The machine has to be switched OFF and disconnected from the line before you perform any
work in the area of the cutter.
X In addition, the compressed air supply must be turned off at the main valve of the compressed
air unit in the machine base and the compressed air lines must be bled by actuating the
needle valve on the compressed air unit.
X Always secure the machine against unauthorized reactivation, as described in the User
Manual, chapter "Lock-Out and Tag-Out Procedure ...".
WARNING:
X Wear appropriately thick protective gloves when working near the blades/the tape deflector!
X There is a high risk of injury from stationary blades and moveable blades and from the tape
deflector of the cutter, even when the machine has been turned off!
X Never reach into the pneumatic cutter from below or into the empty-tape duct from above, not
even to resolve a problem (e.g. when tape is jammed).