00195166-0402_SM_D4_EN.pdf - 第118页
Service Work Modular Conveyor Replacing the DC Geared Motor [03 009269] 118 Serv ice Manual SIPLACE D4 4.4.3 Replacing the DC Geared Motor [03009269] Overview Removal Legend 1. DC geared mo tor 2. Fastening screws 3. Too…

Service Work
Replacing the Complete Drive Unit [00359284] Modular Conveyor
Service Manual SIPLACE D4
117
Installation
See also:
J
6.5.1 Adjusting the Tension of the Conveyor Toothed Belt [
J
242]
X Strip the heat-shrinkable sleeve, (2) used to
fasten the connection cable, from the
circumference of the DC geared motor.
NOTE:
If necessary, loosen the deflection
pulley at the slot (6). This will make it
easier to unthread the motor mount.
Then correct the belt tension.
X Remove the 3 screws (3) holding the motor
mount in place (5).
X Push the hexagonal shaft back and carefully
remove the motor mount (5). At the same time,
carefully unthread the conveyor toothed belt.
ATTENTION: Do not damage the
toothed belt!
The toothed belts must not be
stretched or kinked!
NOTE:
The way in which the conveyor toothed belt is run around the belt guide depends upon the
transport area concerned. Please observe this belt guidance during assembly.
NOTE:
If you have discovered a break in the motor cable during a continuity check, the motor cable
must be unthreaded as far as the conversion board of the conveyor side (see circuit diagrams
of the same name) and unplugged at the corresponding point. This might be somewhat
complicated depending on the routing of cables inside the machine base.
X You may wish to contact SIPLACE Service regarding this work.
X Fit the new drive unit in the reverse order.
X Please check:
The entire width of the conveyor toothed belt
(1) must engage at all toothed disks (2) and be
run around the belt guide (3).
X Perform the Final steps including function
test.
NOTE:
After the new drive has been installed,
you must make certain that the
direction of rotation and the conveyor
speed (motor voltage) are correct.
After reconnecting the geared motor,
you only need to check the direction of
rotation.

Service Work
Modular Conveyor Replacing the DC Geared Motor [03009269]
118 Service Manual SIPLACE D4
4.4.3 Replacing the DC Geared Motor [03009269]
Overview
Removal
Legend
1. DC geared motor
2. Fastening screws
3. Toothed disk (conveyor toothed belt)
4. Toothed disk (toothed belt for PCB conveyor
drive)
The DC geared motors, including the motor
mounts of all 5 conveyor areas, are of like
construction. Please bear in mind the following
differences during assembly and disassembly:
The motor mount is installed at an angle
(tilted), according to the requirements of the
installation site.
1
4
3
2
X Move the PCB conveyor to a position in which
the fastening screws (2) are accessible.
X Switch off the machine and secure it to prevent
unauthorized reactivation.
X Mark the polarity (+ / -) of the cable
connections (1) - important for the direction of
rotation!
X Disconnect the cable shoes from the motor
terminals (1).
X Strip the heat-shrinkable sleeve, (4) used to
fasten the connection cable, from the
circumference of the DC geared motor.
X From the outer side of the conveyor, undo the
fixtures holding (2) the DC geared motor (5).
X Tilt the DC geared motor (5) a little, so that the
small toothed belt (3) comes free of the
toothed disk.
ATTENTION: Do not damage the
toothed belt!
The toothed belts must not be
stretched or kinked!
X Pull the DC geared motor out.
X Please note:
The toothed disk on the motor shaft must be
moved out in such a manner that it does not
get caught in the toothed belt.
5
1
4
3
2

Service Work
Replacing the DC Geared Motor [03009269] Modular Conveyor
Service Manual SIPLACE D4
119
Installation
NOTE:
If you have discovered a break in the motor cable during a continuity check, the motor cable
must be unthreaded as far as the conversion board of the conveyor side (see circuit diagrams
of the same name) and unplugged at the corresponding point.
This might be somewhat complicated depending on the routing of cables inside the machine
base.
You may wish to contact SIPLACE Service regarding this work.
ATTENTION: Do not damage the
toothed belt!
The toothed belts must not be
stretched or kinked!
X Fit the new DC geared motor (5) by following
the above instructions in reverse order.
The entire width of the toothed belt (3) must
engage at the top and bottom toothed disks.
X Fix the DC geared motor (5) with the 4 M3
hexagonal socket-head screws (2).
X Tension the toothed belt (3) by moving the DC
geared motor in the fastening holes. The belt
tension must be between
10 and 15 N.
X Reconnect to the electrical system (1) and
secure the connection cable with a heat-
shrinkable hose (4).
NOTE:
After the geared motor has been
installed, you must make certain that
the direction of rotation and the
conveyor speed (motor voltage) are
correct.
5
1
4
3
2