00195166-0402_SM_D4_EN.pdf - 第262页
Settings Conveyor Conveyor Contro l TSP 301 262 Serv ice Manual SIPLACE D4 6.5.12.3 LED Display on Conveyor Control TSP 301 6.5.12.4 Assignment T able: LEDs on the TSP 301 Conveyor Control 6-47: Conveyor Control TSP 301 …

Settings
Conveyor Control TSP 301 Conveyor
Service Manual SIPLACE D4
261
6.5.12.2 Conveyor Control TSP 301 with Siemens Interface
6-45: TSP 301 SMEMA --> Siemens
NOTE: Standard / Option
The SMEMA interface is a standard on
all X machines and the Siemens
interface is optional.
The Siemens interface is a standard on
all D machines and the SMEMA
interface is optional. The SMEMA
interface requires an adapter when
used with the D1/2/4.
WARNING: Risk of irreparable
damage to the TSP board!
The 10 pin Locking clip plug of SMEMA
connections must be disconnected
from the TSP 301!
Application: no modification.
Following modification are necessary for using the
Siemens interface:
X JumperJ1 / J2: need to be moved (see
following diagram).
X Disconnect the connector X3 and X4 on the
TSP 301!
X Connect the Siemens interface cable on the
connector X1 and X2.
Legend
1. 10-pin plug for SMEMA interface
X3: upstream station
X4: successor station
2. Connection for Siemens interface
X1: upstream station
X2: successor station
6-46: Jumper J1 and J2 (Siemens/SMEMA)

Settings
Conveyor Conveyor Control TSP 301
262 Service Manual SIPLACE D4
6.5.12.3 LED Display on Conveyor Control TSP 301
6.5.12.4 Assignment Table: LEDs on the TSP 301 Conveyor Control
6-47: Conveyor Control TSP 301
Legend
1. Connector for Siemens PCB handling
interface of predecessor station, lane 1 with
corresponding PCB handling LEDs
2. Connector for Siemens PCB handling
interface of successor station, lane 1 with
corresponding PCB handling LEDs
The "Siemens board handling interface for the
predecessor station of lane 2 with corresponding
LEDs for board handling" plug and the "board
handling interface for the successor station of lane
2 with corresponding LEDs for board handling"
plug are located on the extension board (similar
layout).
Anzeige
/Display
I / O LED assignment
H1 / F1-F5 Fuse F1-F5, Power supply 40 V
H2 / F6 Fuse F6 Power supply 24V
H4(ao) Initializing / control error
H5(ao) CAN bus 1, active
H6(ao) Flashing: Program running
H7(ao) CAN bus 2, active (optional)
H9 Out Interference loop
H14 IN Siemens interface for upstream station
H15 IN Siemens interface for downstream station
H20 IN Lifting table, placement area 1: Fork light barrier A
H21 IN Lifting table, placement area 1: Fork light barrier B
H22 IN Lifting table, placement area 2: Fork light barrier A

Settings
Conveyor Control TSP 301 Conveyor
Service Manual SIPLACE D4
263
H23 IN Lifting table, placement area 2: Fork light barrier B
H24 IN Laser light barrier, placement area 1: Receiver
H25 IN Laser light barrier, placement area 2: Receiver
H26 IN Not in use
H27 IN Not in use
H28 IN Not in use
H29 IN Not in use
H30 IN Lifting table, placement area 1: Cylinder switch
H31 IN Lifting table, placement area 2: Cylinder switch
H32 IN Right side part: Limit switch
H33 IN Left side part: Limit switch
H34 IN Width adjustment Limit switch, Limit switch, right-hand side
H35 IN Not in use
H36(ao) IN Width adjustment unit 1 : Cylinder switch
H37(ao) IN Width adjustment unit 2 : Cylinder switch
H38(ao) IN Width adjustment unit 1 : Sensor side part
H39(ao) IN Width adjustment unit 2 : Sensor side part
H40(ao) IN Width adjustment spindle: Limit switch, right-hand side
H41(ao) IN Width adjustment spindle: Limit switch, left-hand side
H42(ao) IN Not in use
H43(ao) IN Not in use
H44 IN PCB sensor for input conveyor
H45 IN PCB sensor for placement area 1
H46 IN PCB sensor for intermediate conveyor
H47 IN PCB sensor for placement area 2
H48 IN PCB sensor for output conveyor
H49 IN Not in use
H50 IN Not in use
H51 IN Not in use
H52 IN Light scanner "Fluxing", input conveyor
H53 IN Light scanner "Fluxing", placement area 1
H54 IN Light scanner "Fluxing", intermediate conveyor
H55 IN Light scanner "Fluxing", placement area 2
H56 IN Light scanner "Fluxing", output conveyor
H57 IN Not in use
H58 IN Option plug, placement area 1: Input 1
H59 IN Option plug, placement area 1: Input 2
H60 IN Option plug, placement area 1: Input 3
H61 IN Option plug, placement area 1: Input 4
H62 IN Option plug, placement area 1: Input 5
H63 IN Option plug, placement area 1: Input 6
Anzeige
/Display
I / O LED assignment