00195166-0402_SM_D4_EN.pdf - 第196页
Service Work C&P12 Placement Head Press Fit Connections with Fixture Clips on the Vision Board ( D Series) 196 Serv ice Manual SIPLACE D4 4.5.22 Press Fit Connections with Fixtur e Clip s on the Vision Board (D Serie…

Service Work
Checking the Cable Routing C&P12 Placement Head
Service Manual SIPLACE D4
195
4.5.21.4 Running the Valve Positioning Drive Cables
Avoid loose cables.
The diagram shows the board support to the side
of the placement head and the illumination board
(4) on the component camera.
The connection cables for the valve positioning
drives (1) of the reject and placement circuits need
to be fixed at the bolt of the board holder (3) with a
cable tie (2).
CAUTION: Wrap insulating tape
around bare bolts
If the bolts are not already covered with
a plastic hose, as shown here, wrap
insulating tape around the fixture point.

Service Work
C&P12 Placement Head Press Fit Connections with Fixture Clips on the Vision Board (D Series)
196 Service Manual SIPLACE D4
4.5.22 Press Fit Connections with Fixture Clips on the Vision Board (D Series)
4.5.23 Replacing the Raceway (Circular Arc Guide)
ATTENTION: Do not damage the fixture clips!
To disconnect the component and PCB camera connections, you need to open the fixture clips
by applying pressure to the side of the connector.
The adjacent diagram shows the press-fit
connections for the component camera (1) and the
PCB camera (2) on the Vision board of the
SIPLACE D1/D2. Each of the two positions has
two connectors of different sizes with fixture clips.
Z To release the press-fit connections, press the
connector sides together at the top, with your
thumb and index finger.
X The fixture clips will open and the connector
can be pulled up and off.
> The adjacent diagram shows the two press-fit
connections arranged one above the other, for
the Vision signals (small connector) and
illumination control (large connector) after
disconnection of the connectors.
NOTE:
This service task may only be performed by specially trained SIPLACE service technicians.
The procedure is described in a separate manual.

Service Work
Replacing the Membrane (Vacuum Plate) on the Sleeve [00354244-xx] C&P12 Placement Head
Service Manual SIPLACE D4
197
4.5.24 Replacing the Membrane (Vacuum Plate) on the Sleeve [00354244-xx]
The sealing membrane on the sleeves ensures sufficient vacuum by sealing the tip of the nozzle (serves
as the air inlet) in the sleeve.
Tools and Equipment
Standard tool
Spare part: membrane (vacuum plate) [00354244-xx]
Removal/Installation
X Loosen the old membrane with an Allen key (1.5 mm) and remove the membrane.
X Fit the new membrane onto the sleeve and tighten the membrane with an Allen key.
Blue membrane for the sleeve with ball fixing
C&P6/12
White membrane for the sleeve with ball fixing
C&P6/12, made of an alternative material
Expected release 10/2008
ATTENTION: Do not use a ball Allen key
X Make sure that you do not use a ball Allen key.
X The new, white version of the membrane should be available from 10/2008.