80S-2080F480F5.pdf - 第122页
2 Introduction and Ba sic Concepts SIPLACE 80S-20/F4/F5 User Manual 2.4 Brief Description and Principles of the User Interface 05/99 I ssue from Software Version SR.405.xx 2 - 38 2.4.3.4 Vision Functions The visio n func…

SIPLACE 80S-20/F4/F5 User Manual 2 Introduction and Basic Concepts
05/99 Issue from Software Version SR.405.xx 2.4 Brief Description and Principles of the User Interface
2 - 37
2.4.3.3 Single Functions
The Single functions are the gantry functions and transport functions.
The Single functions are used to execute certain actions after fatal errors and for setting up and testing the
automatic placement machine. The Single functions are also used to activate various functional modules in a
predefined manner.
PLEASE NOTE
The complete range of Single functions is described in Chapter 4 of this User Manual.
l Gantry functions
The "Gantry functions“ menu is used to execute various functions at the gantry under consideration.
For the head functions, it is important to differentiate between the SIPLACE 80S20 and the F
4
/F
5
.
The SIPLACE 80S20 has two gantries, each with a 12-segment star head, that can be activated separately
(buttons for gantry 1 and gantry 2). The functions are identical.
The Siplace 80F
4
has one gantry with a 12-segment star head and an IC head, which can both be activated
separately, although their functions are different.
The Siplace 80F
5
has one gantry with a 6-segment star head and an IC head, which can both be activated
separately, although their functions are different.
l Transport functions 1
The transport functions are used for checking and setting the functional modules of the PCB conveyor and for
adjusting the transport width.
l Transport functions 2 (option)
The transport functions 2 are only active if the
Twin conveyor
option is installed. The functions in this menu
are the same as those in Transport functions 1.

2 Introduction and Basic Concepts SIPLACE 80S-20/F4/F5 User Manual
2.4 Brief Description and Principles of the User Interface 05/99 Issue from Software Version SR.405.xx
2 - 38
2.4.3.4 Vision Functions
The vision functions are used to execute the Teach / Test fiducials, Measure component and Change package
form data functions.
PLEASE NOTE
The complete range of vision functions is described in Chapter 4 of this User Manual.
l Teach fiducials (line engineer functions)
The "Teach fiducials“ menu is used to edit fiducials for the PCB position detection system.
l Test component (line engineer functions)
The "Test component“ menu is used to edit package forms for component centering.
2.4.3.5 Start SITEST
This option is used to start the SITEST package for setting up and calibrating the automatic placement
machine.
The user interface and the range of SITEST functions is described in the separate SITEST User Manual.
2.4.3.6 GEM Interface (Option)
In the GEM menu, you can modify and execute the functions of the GEM interface.
PLEASE NOTE
The complete range of functions in the GEM menu is described in Section 11.9 of this User Manual.

SIPLACE 80S-20/F4/F5 User Manual 2 Introduction and Basic Concepts
05/99 Issue from Software Version SR.405.xx 2.4 Brief Description and Principles of the User Interface
2 - 39
2.4.4 The Options Menu
This contains a range of additional and operator functions.
Fig. 2.4.4 The "Options" menu