SIPLACE 80S-20/F4/F5 User Manual 4 Single Functions
05/99 Issue from Software Version SR.405.xx 4.2 Single Functions, Gantry with 12x Revolver Head
4 - 7
4.2.1.2 Go to Service Position
At the service position the gantry is at a position in which it is possible to carry out work on the placement
head or on other parts of the gantry.
Click on the
Go to service position
button and press the start button as often as you are asked to do so.
The gantry will move into the service position.
4.2.1.3 Go to Waiting Position
The waiting position is that position in the machine to which the gantry moves when it is not required for place-
ment.
Click on the
Go to waiting position
button and press the start button as often as you are asked to do so.
The gantry will move into the waiting position.
4.2.1.4 Go to Zero Pulse
Zero pulse is the position of the gantry to which the counting procedures of the incremental encoder refer.
Click on the
Go to zero pulse
button and press the start button as often as you are asked to do so. The
gantry will move to the zero pulse position of the x and y axes.
4.2.1.5 Gantry Reference Run
The
Gantry reference run
function causes the active gantry to perform a reference run with the x and y axes.
Click on the
Gantry reference run
button and press the start button as often as you are asked to do so.
The gantry will perform a reference run.

4 Single Functions SIPLACE 80S-20/F4/F5 User Manual
4.2 Single Functions, Gantry with 12x Revolver Head 05/99 Issue from Software Version SR.405.xx
4 - 8
4.2.2 Revolver Head Functions, 12x Revolver Head
In the
Revolver head functions
menu you can control revolver head functions.
NOTE
When the cover is open the revolver head functions can be carried out only when the key-operated switch has
been turned.
In the
Gantry functions
menu, click on the symbol button for
Revolver head functions.
The current position of the star will be shown each time.
Fig. 4.2.3 Revolver head functions, 12x revolver head
4.2.2.1 Star in Position 1
This function is used for bringing the star into a defined starting position. To this end the star and the z axis
perform a reference run.
Click on the Star in position 1 button. The star will then be moved until the segment of star position 1 is in
the pick-up and placement position (the lowest position).
F

SIPLACE 80S-20/F4/F5 User Manual 4 Single Functions
05/99 Issue from Software Version SR.405.xx 4.2 Single Functions, Gantry with 12x Revolver Head
4 - 9
4.2.2.2 Star step
This function is used for advancing the star one position at a time.
Click on the
Step
button. The star will be advanced by one segment. Each time you click the star will be
moved forward by one segment. The current position of the star is shown in the diagram.
4.2.2.3 Actuate DP Axis
When this function is activated the nozzle in the dp1 axis is rotated by 90
o
.
Click on the
Actuate dp axis
button. The nozzle in the dp1 axis will be rotated by 90
o
once.
4.2.2.4 Pick-Up Circuit - Forced Air On / Off
When this function is activated, the forced air at the pick-up position will be switched on or off.
Within the
Pick-up circuit
working area click on the
Forced air on / off
button. At the nozzle which is in
the pick-up position the forced air will be switched on or off.
4.2.2.5 Pick-Up Circuit- Measure Forced Air
When this function is activated, the activated forced air at the pick-up position will be measured.
Switch the forced air on.
Within the
Pick-up circuit
working area click on the
Measure forced air
button. At the nozzle which is in
the pick-up position the forced air will be measured. The results of measurement will be shown in the dis-
play window.
PLEASE NOTE
The values shown in the window do not correspond to the actual values at the nozzle.
When the settings are made, the values are determined using a manometer (see Adjustment instructions
or the Service Manual).
Switch the forced air off.
4.2.2.6 Pick-Up Circuit - Vacuum On / Off
When this function is activated, the vacuum at the pick-up position will be switched on or off.
Within the Pick-up circuit working area click on the Vacuum on / off button. At the nozzle which is in the
pick-up position the vacuum will be switched on or off.