SIPLACE 80S-20/F4/F5 User M anual 9 Maintenance 05/99 Issue from Software Vers ion SR.405.xx 9.3 Machine B ase 9 - 37 9.3.8 Safety Hoods 9.3.8.1 Cleani ng the Guideway DANGER Do not c arry out an y cleani ng work with al…

100%1 / 763
9 Maintenance SIPLACE 80S-20/F4/F5 User Manual
9.3 Machine Base 05/99 Issue from Software Version SR.405.xx
9 - 36
Starting at the
Gantry 1 functions
menu, select
IC head functions
Return
.
In the
Gantry functions
menu, select the
Go to waiting position
option. This moves the IC head to an
area outside of the nozzle changer.
DANGER
Switch off the automatic placement systems at the main switch and disconnect from the power supply.
Open the sliding safety door above the IC head.
Remove the nozzles manually one by one from the nozzle changer.
To do so, place the nozzle removal tool on the nozzle, as shown in Fig. 9.6.8, page 9 - 73. Turn the nozzle
clockwise as far as the stop and until it disengages. Lift away the tool. Now remove the nozzles by hand
from the nozzle changer.
As you remove each nozzle make a note of its garage number and nozzle type, or have them displayed
again following maintenance in the
Nozzle configuration IC-head
menu.
Clean out the locating holes in the nozzle changer with the vacuum cleaner, and clean also in this way the
bearing surface and countersink of each hole, if necessary using a brush and some alcohol. Finally, dry off
the holes.
NOTE:
You have the assignments of the nozzle types to the garage number displayed on the screen in this way:
Gantry 1 functions
menu
Nozzle configuration IC head
. The ACTUAL and PROGRAMMED assign-
ments are shown on the screen. Make sure you restore the ACTUAL assignments.
Carry out maintenance on the nozzles whenever possible before replacing the nozzles in the nozzle
changer.
After this, replace the nozzles in the correct allocated positions in the nozzle changer.
When placement is resumed, the actual nozzle will be picked up again automatically. However a precondi-
tion of this is that you have, as described above, returned the nozzle using the
Return nozzle
function.
SIPLACE 80S-20/F4/F5 User Manual 9 Maintenance
05/99 Issue from Software Version SR.405.xx 9.3 Machine Base
9 - 37
9.3.8 Safety Hoods
9.3.8.1 Cleaning the Guideway
DANGER
Do not carry out any cleaning work with alcohol in the presence of naked lights or fire!
DANGER
Switch off the automatic placement systems at the main switch and disconnect from the power supply.
Use a vacuum cleaner nozzle to thoroughly clean the area of the two guideways along the long side of the
machine. Move the safety hood as required.
Clean the guide rails on both long sides of the side panel of the safety hoods with a brush dipped in alco-
hol.
Slide the safety hoods apart until you can see a gap in the guide rail between the safety hoods.
Apply a small quantity of Staburags N12 to this gap and move the safety hoods repeatedly back and forth
to spread the grease evenly.
If necessary, wipe over the safety hoods with a cloth soaked in alcohol.
9.3.8.2 Cleaning the Bar Code Strip
The position of the bar code strips on the machine is shown in Fig. 9.1.1, page 9 - 3.
Clean the bar code strips (used in connection with the supply of components) on the two side covers with
a soft dry cloth.
NOTE
The bar code strips are glued on. Do not use alcohol when cleaning. Otherwise the labels could come off.
9 Maintenance SIPLACE 80S-20/F4/F5 User Manual
9.3 Machine Base 05/99 Issue from Software Version SR.405.xx
9 - 38
9.3.8.3 Cleaning the protective covers
Clean the protective covers with a soft, dry cloth, if necessary.
Clean the protective covers with alcohol if they are very dirty.
CAUTION
Do not use any cleaning agents other than water or ethyl alcohol to clean the protective covers.
Only use soft cloths for cleaning.
Otherwise you will damage the EGB protective coating on the protective covers.
PLEASE NOTE:
Do not use alcohol to clean the barcode strips because they are glued on and could fall off.