80S-2080F480F5.pdf - 第471页
SIPLACE 80S-20/F4/F5 User M anual 9 Maintenance 05/99 Issue from Software Vers ion SR.405.xx 9.1 Overview 9 - 5 9.1.3 SIPLACE 80F 5 Placement Machine Fig. 9.1.3 SIPLACE 80F 5 : Modules requiring maintenance - Key to Fig.…

9 Maintenance SIPLACE 80S-20/F4/F5 User Manual
9.1 Overview 05/99 Issue from Software Version SR.405.xx
9 - 4
9.1.2 SIPLACE 80F
4
Placement Machine
Fig. 9.1.2 SIPLACE 80F
4
: Modules requiring maintenance
- Key to Fig. 9.1.2
1 12 x revolver head, gantry 1 10 Empty tape cutters
2 IC head 11 PCB transport
3 X axis, gantry 1 12 Rejects container for the revolver head
4 Y axis, gantry 1 13 Rejects container for IC head, component
5 Safety hoods with guide rails vision camera, coplanarity laser module
6 Compressed air unit and nozzle changer
7 Servo unit, filter mat 14 Control unit of PCB Handling
8 Control unit, filter mat 15 Bar code strips
9 Changeable components tables 16 Wafflepack changer

SIPLACE 80S-20/F4/F5 User Manual 9 Maintenance
05/99 Issue from Software Version SR.405.xx 9.1 Overview
9 - 5
9.1.3 SIPLACE 80F
5
Placement Machine
Fig. 9.1.3 SIPLACE 80F
5
: Modules requiring maintenance
- Key to Fig. 9.1.3
1 6 x revolver head, gantry 1 10 Empty tape cutters
2 IC head 11 PCB transport
3 X axis, gantry 1 12 Rejects container for the revolver head
4 Y axis, gantry 1 13 Rejects container for IC head, component
5 Safety hoods with guide rails vision camera, coplanarity laser module
6 Compressed air unit and nozzle changer
7 Servo unit, filter mat 14 Control unit of PCB Handling
8 Control unit, filter mat 15 Bar code strips
9 Changeable components tables 16 Wafflepack changer

9 Maintenance SIPLACE 80S-20/F4/F5 User Manual
9.1 Overview 05/99 Issue from Software Version SR.405.xx
9 - 6
9.1.4 General Information (SIPLACE 80S-20, 80F
4
, and 80F
5
)
9.1.4.1 Safety Instructions
DANGER
•
When carrying out any work you must comply with the safety instructions in this user’s manual.
• The key-operated switch may be unlocked only by authorized persons and once work is completed
the key must be kept under lock.
• Do not carry out any cleaning work with alcohol in the presence of naked lights or fire.
• Always keep to the order of work specified.
DANGER
The coplanarity laser module can be installed as an option on Siplace 80F
4
and 80F
5
automatic placement
systems. The laser operates within a power and wavelength range which is hazardous for the skin and eyes.
For this reason special safety rules apply; see also the Section 9.9.5 on page 9 - 102.
Do not tamper in any way whatsoever with the safety devices!
Fault correction and repairs to the laser module and safety plug must be carried out by the manufacturer.
9.1.4.2 Information on the Sequence of Work
NOTE
The maintenance frequencies specified for the checking and replacing the filter elements apply only for the
specified compressed air quality, see Compressed Air Specification. Otherwise increase maintenance fre-
quencies accordingly.
Make a note in the maintenance schedule of the maintenance work which has been carried out.
We recommend you keep to the sequence of work specified in the maintenance schedule.
NOTE
If you wish to move the gantry by hand after switching off the SIPLACE 80F
4
or 80F
5
placement machine it is
essential that you observe the following information:
The z axis (sleeve) must be in its top end position after the machine is switched off. If this is not the case, this
indicates a fault. You should inform the SMD service department.