80S-2080F480F5.pdf - 第189页

SIPLACE 80S-20/F4/F5 User M anual 4 Single Functions 05/99 Issue from Software Version SR.405.xx 4.2 Single Functions, Gantry with 12x Revolver Head 4 - 13 4.2.3.4 Head Reference Run When th is functi on is ac tivated, t…

100%1 / 763
4 Single Functions SIPLACE 80S-20/F4/F5 User Manual
4.2 Single Functions, Gantry with 12x Revolver Head 05/99 Issue from Software Version SR.405.xx
4 - 12
4.2.3.2 Nozzle - Return
When this function is activated, the nozzle found at the IC head can be returned. The current nozzle will be
displayed.
Within the
Nozzle
working area click on the
Return
button. The nozzle which is at the IC head will be
returned.
4.2.3.3 Nozzle - Pick Up
When this function is activated, the various nozzles which are included in the nozzle-changer set-up can be
picked-up.
Within the
Nozzle
working area click on the
Pick up
button. The following input window will appear.
Fig. 4.2.5 IC head functions: pick up nozzle
Type the number of the nozzle which is to be picked up into the input field of the input window.
Click on the OK button. The nozzle selected will be picked up and displayed in the display window.
NOTE
If there is a nozzle at the IC head, it will be returned first.
F
SIPLACE 80S-20/F4/F5 User Manual 4 Single Functions
05/99 Issue from Software Version SR.405.xx 4.2 Single Functions, Gantry with 12x Revolver Head
4 - 13
4.2.3.4 Head Reference Run
When this function is activated, the z and d axes will carry out a reference run.
Within the working area click on the
Head reference run
button. The z and d axes will carry out a refer-
ence run.
4.2.3.5 Turn D Axis
When this function is activated, you can check the d axis. For the check the d axis is rotated.
Within the working area click on the
Turn d axis
button. The d axis will rotate.
4.2.3.6 Z Axis - Unclamp
When this function is activated, clamping of the z axis will be released.
Within the
Z axis
working area click on the
Unclamp
button. The clamping of the z axis is released and a
message window appears.
To activate clamping click on the
OK
button. The message window will be closed and clamping of the z
axis is active.
4.2.3.7 Vacuum - On
When this function is activated, the vacuum is switched on.
Within the
Vacuum
working area click on the
On
button. The vacuum will be switched on.
4.2.3.8 Vacuum - Off
When this function is activated, the vacuum is switched off.
Within the
Vacuum
working area click on the
Off
button. The vacuum will be switched off.
4.2.3.9 Forced Air - On
When this function is activated, forced air is switched on at the nozzle. At the same time, if vacuum is active it
will be switched off.
Within the Forced air working area click on the On button. Forced air will be switched on.
4.2.3.10 Forced Air - Off
When this function is activated, forced air is switched off at the nozzle.
Within the Forced air working area click on the Off button. Forced air will be switched off.
4 Single Functions SIPLACE 80S-20/F4/F5 User Manual
4.2 Single Functions, Gantry with 12x Revolver Head 05/99 Issue from Software Version SR.405.xx
4 - 14
4.2.4 Vacuum Test, 12x Revolver Head
If all nozzles are at the star, when this function is activated the nozzles will be checked regarding their vacuum
values in the pick-up position.
In the
Gantry functions
menu click on the symbol button for
Vacuum test revolver head.
Fig. 4.2.6 Vacuum test 12x revolver head
Click on the
Measure
button. A head reference run will be carried out and the vacuum values at the pick-
up position measured for all nozzles. The measured values for the open and closed pick-up positions are
displayed.
F