80S-2080F480F5.pdf - 第584页
10 Component Handling SIPLACE 80 S20/F4/F5 User Manual 10.3 Component table, mobile 05/99 Issue from Software Version SR.405.xx 10 - 12 10.3.2 Undocking the component t able Fig. 10.3.2 Undocking the mobile component

SIPLACE 80 S20/F4/F5 User Manual 10 Component Handling
05/99 Issue from Software Version SR.405.xx 10.3 Component table, mobile
10 - 11
10.3 Component table, mobile
10.3.1 Safety instructions for docking and undocking the mobile com-
ponent table
WARNING
Never reach into the gap between the component tables and the placement system frame while the
machine is running (item 1).
Always check that the component table is docked on the placement system before connecting or discon-
necting the component table power cable at the socket on the placement system (item 2).
NEVER connect the component table connecting cable to the socket on the placement system and then
operate the component table via the external compressed air control unit (item 3).
Fig. 10.3.1 Safety instructions for the mobile component table

10 Component Handling SIPLACE 80 S20/F4/F5 User Manual
10.3 Component table, mobile 05/99 Issue from Software Version SR.405.xx
10 - 12
10.3.2 Undocking the component table
Fig. 10.3.2 Undocking the mobile component

SIPLACE 80 S20/F4/F5 User Manual 10 Component Handling
05/99 Issue from Software Version SR.405.xx 10.3 Component table, mobile
10 - 13
Key to Fig. 10.3.1
(1) Communication interface connector
(2) Power supply connector for the component table
(3) Compressed air connection
(4) Component table bed
(5) Button for raising and lowering the component table bed
(6) Actuating tube
(7) Fold-down bracket
(8) Holes for the centering pins
(9) Centering pins
(10) Contact surfaces for the slide rails of the component table
(11) Horizontal tensioners
Click on the PAUSE OPERATION icon in the BASIC VIEW menu.
The PCB in progress will be completed. The icons of the SINGLE FUNCTIONS menu will then be acti-
vated.
Click on the desired SINGLE FUNCTIONS GANTRY X icon (gantry 1 or 2).
Click on the GANTRY FUNCTIONS icon.
From this menu, click on the APPROACH SET-UP POSITION button.
The selected placement head will move across the PCB transport to prevent it being damaged when the
component table is changed.
Open protective cover of the selected gantry.
Open the side screens.
Open the horizontal tensioners (item 11)
Pull the two actuating tubes (item 6) towards you at the same time and lift up the bracket (item 7) to lock
the raised component table bed in its top end position.
Hold down the button (item 5) for raising the component table bed (item 4) until the component table bed
reaches its top end position.
Unplug the component table power cable (item 2).
Unplug the component table control cable (item 1).
Disconnect the compressed air supply (item 3).
Remove the component table.