CM88Maintenace1.pdf - 第103页
Page 1-65 REGULAR MAINTENANCE 1 Check Every 1000 Hours (Once T wo Months) 5 . Press UNLOCK and Head rotation . • 3 transfer heads on the rear side of machine of main axis rotate by 180°. 6 . T urn off the servo switch. 7…

Page 1-64
Check Every 1000 Hours (Once Two Months)
3. Setting the transfer head
1. Set the transfer head to the elevating
unit.
∗ Adjust positions of positioning hole of holder
and positioning pin at the bottom of elevating
unit.
∗ Tighten three bolts in front of the housing with
a hexagonal wrench.
2. Set the nozzle holder.
“1-4-1 Cleaning and Changing the
Nozzles”
∗ Be careful not to set the nozzle at the wrong
position (nozzle position).
3. Close the rear center safety cover.
4. Turn on the servo switch.
OFF ( )
ON ( )
SERVO
3Y3C-051
3Y3C-AG01
3Y3C-E-MMD01-A06-02
Main axis
3Y3C-122E
Rear side
Main axis
3Y3C-138E
Rear side
H11
2
3
To the next page
Nozzle position
3Y3C-139E

Page 1-65
REGULAR
MAINTENANCE
1
Check Every 1000 Hours (Once Two Months)
5. Press
UNLOCK
and Head rotation .
• 3 transfer heads on the rear side of machine of
main axis rotate by 180°.
6. Turn off the servo switch.
7. Open the rear center safety cover.
8. Set other nozzles.
9. Close the rear center safety cover.
10. Turn on the servo switch.
3Y3C-E-MMD01-A06-02
OFF ( )
ON ( )
SERVO
Main axis
3Y3C-AI01
3Y3C-141E
Rear side
OFF ( )
ON ( )
SERVO
3Y3C-AG01
3Y3C-112P
Main axis
3Y3C-142E
Rear side
To the next page

Page 1-66
Check Every 1000 Hours (Once Two Months)
11. Press
UNLOCK
and Main axis step .
• Main axis moves by steps.
12. After that, repeat the procedures 1. to
11. and set all transfer heads.
13. Press Nozl set chk .
Procedures of nozzle setting
“1-4-1 Cleaning and Changing the Nozzles”
∗ Continue the operation to “Head exchange
teach.”
Main axis
3Y3C-143E
Rear side
3Y3C-E-MMD01-A06-02