CM88Maintenace1.pdf - 第103页

Page 1-65 REGULAR MAINTENANCE 1 Check Every 1000 Hours (Once T wo Months) 5 . Press UNLOCK and Head rotation . • 3 transfer heads on the rear side of machine of main axis rotate by 180°. 6 . T urn off the servo switch. 7…

100%1 / 166
Page 1-64
Check Every 1000 Hours (Once Two Months)
3. Setting the transfer head
1. Set the transfer head to the elevating
unit.
Adjust positions of positioning hole of holder
and positioning pin at the bottom of elevating
unit.
Tighten three bolts in front of the housing with
a hexagonal wrench.
2. Set the nozzle holder.
“1-4-1 Cleaning and Changing the
Nozzles”
Be careful not to set the nozzle at the wrong
position (nozzle position).
3. Close the rear center safety cover.
4. Turn on the servo switch.
OFF ( )
ON ( )
SERVO
3Y3C-051
3Y3C-AG01
3Y3C-E-MMD01-A06-02
Main axis
3Y3C-122E
Rear side
Main axis
3Y3C-138E
Rear side
H11
2
3
To the next page
Nozzle position
3Y3C-139E
Page 1-65
REGULAR
MAINTENANCE
1
Check Every 1000 Hours (Once Two Months)
5. Press
UNLOCK
and Head rotation .
3 transfer heads on the rear side of machine of
main axis rotate by 180°.
6. Turn off the servo switch.
7. Open the rear center safety cover.
8. Set other nozzles.
9. Close the rear center safety cover.
10. Turn on the servo switch.
3Y3C-E-MMD01-A06-02
OFF ( )
ON ( )
SERVO
Main axis
3Y3C-AI01
3Y3C-141E
Rear side
OFF ( )
ON ( )
SERVO
3Y3C-AG01
3Y3C-112P
Main axis
3Y3C-142E
Rear side
To the next page
Page 1-66
Check Every 1000 Hours (Once Two Months)
11. Press
UNLOCK
and Main axis step .
Main axis moves by steps.
12. After that, repeat the procedures 1. to
11. and set all transfer heads.
13. Press Nozl set chk .
Procedures of nozzle setting
“1-4-1 Cleaning and Changing the Nozzles”
Continue the operation to “Head exchange
teach.”
Main axis
3Y3C-143E
Rear side
3Y3C-E-MMD01-A06-02