CM88Maintenace1.pdf - 第30页
Page 30 IDENTITY PLA TE AND CAUTION LABEL Both an identity plate and a caution label for this product are attached to the machine. Operate and maintain the machine according to the instructions on the label. ∗ 1 : Identi…

Page 29
Light emitting side
HEIGHT SENSOR UNIT
The CM88 is equipped with the height sensor unit which complies with Interna-
tional Standard IEC 825-1 (1993) as the class 1 light emitting diode unit and its
safety level is defined as “Lasers which are safe under reasonably foreseeable
conditions of operation.” However, if the LED unit disassembled or modified,
and used for the other purpose, the safety for the human being cannot be guar-
anteed. Therefore, great care must be taken when handling.
(1) Object of using the LED product
1
To detect the thickness of a chip picked up.
2
To detect a pick-up miss or tombstoning by detecting
1
.
3
To measure the heights of all nozzles and to control the heights by feeding back measuring
results.
(2) Measuring principle
To detect the nozzle height and the chip thickness by sensing the quantity of the light which comes
through the slit (5 mm × 0.1 mm) in front of the light receiving element.
(3) Location of the LED unit
(4) Specifications for the LED radiation (Laser through-beam photoelectric sensor)
3F3C-IL129
LED Radiation Ident.
Wavelength
(Emitted light wavelength)
Accessible Emission Level
Maximum Power
Estimated Error (10%)
Accessible Emission Level with
Estimated Error
Accessible Emission Limit
(Complies with Japanese
Industrial Standards)
Class
Human Access
Light beam B : Radiated from
the aperture.
800 nm±25 nm continuous wave
>0.17 mW/<0.19 mW
Within 0.02 mW
0.19 mW/0.21 mW
1.96×10
-2
W
Class 1
Operation/Maintenance/Servicing
Light beam A: Radiated from
the light emitting diode.
800 nm±25 nm continuous wave
>0.43 mW/<0.45 mW
Within 0.04 mW
0.47 mW/0.49 mW
1.96×10
-2
W
Class 1
Servicing at the factory
3Y3C-E-MMD00-A04-00
3Y3C-AG01
4W3C-AN00
CM88S-M
CM88S-MU

Page 30
IDENTITY PLATE AND CAUTION LABEL
Both an identity plate and a caution label for this product are attached to the
machine. Operate and maintain the machine according to the instructions on
the label.
∗1 : Identity plate related to “class 1” is not indicated on products for Japan.
∗2 : Nameplates on camera X-Y table and board holder are for maintaining machine’s accuracy.
3Y3C-E-MMD00-A04-00
CM88S-M/M1,CM88C-D (Description is the illustration for CM88S-M.)
B.M/C Height sensor
01DNC0AA
Camera X-Y table
3P3C-PS063
07JFC2AA
4G3C-AE01
Board holder
15ULC0AA
Operator’s side reference:
Attached on inner side.
inner side reference:
Attached on operator’s side.
∗This is attached on the movable side of
conveyor frame.
∗1
∗2
CLASS1 LED
MANUFACTURER : HOKUYO
WAVE LENGTH : 800nm
POWER : 0.5mW
TYPE: VBA-P111R/D111R
∗2
DO NOT TOUCH
DO NOT MOVE THIS CONVEYOR MANUALLY.
CONVEYOR WIDTH WOULD BE CHANGED.
15ULC0AA

Page 31
IDENTITY PLATE AND CAUTION LABEL
CM88S-MU
Camera X-Y table
3P3C-PS063
07JFC2AA
4W3C-AI00
Board holder
15ULC0AA
Operator’s side reference:
Attached on inner side.
inner side reference:
Attached on operator’s side.
∗This is attached on the movable side of
conveyor frame.
∗2
∗2
DO NOT TOUCH
DO NOT MOVE THIS CONVEYOR MANUALLY.
CONVEYOR WIDTH WOULD BE CHANGED.
4W3C-AI00
4W3C-001E
CAUTION
Before changing fuse in
CCU. cut off power.
CCU camera
3Y3C-E-MMD00-A04-00