CM88Maintenace1.pdf - 第141页
Page 1-103 REGULAR MAINTENANCE 1 3Y3C-E-MMD01-A09-01 Changing the Consumable Parts Every 1500 to 6000 Hours 5 . Rotate the main axis motor by hand, and adjust it to 537 pulse. 6 . Check that the thickness gauge (thicker …

Page 1-102
Changing the Consumable Parts Every 1500 to 6000 Hours
4. Adjusting setting position
1. Store the nozzle by hand.
2. Slowly move the nozzle drawing claw
in the right direction, and fix the bolt
at the position where the nozzle has
just dropped.
3. Rotate the main motor in the reverse
direction about 30 pulse, and store
the nozzle by hand.
4. Slowly rotate the main motor rightly,
and when the nozzle clicks in falling
down, adjust the pulse of axis infor-
mation to 473 ± 5.
NOTICE
When there is the head below 468 pulse after checking all heads, adjust it to the
standard one again, considering it as a reference.
3Y3C-E-MMD01-A09-01
Reverse rotation
3Y3C-113P
Right rotation
CAUTION
Be carefull not to be injured
with the edge of nozzle.
3Y3C-120P
3Y3C-120P
Nozzle extension claw
To the next page

Page 1-103
REGULAR
MAINTENANCE
1
3Y3C-E-MMD01-A09-01
Changing the Consumable Parts Every 1500 to 6000 Hours
5. Rotate the main axis motor by hand,
and adjust it to 537 pulse.
6. Check that the thickness gauge
(thicker than 0.1 mm) can be inserted
between the nozzle drawing claw and
nozzle stopper.
3Y3C-113P
3Y3C-070P
Thickness gauge
Nozzle extension claw
Right rotation

Page 1-104
Changing the Consumable Parts Every 1500 to 6000 Hours
5. Checking action after setting
After setting the nozzle extension claw, check the proper setting.
1. Move the coupling of main axis by
hand, so that “Main” on the “Axis
information” screen gets near to “0.”
∗ Make sure that it is within 0 ± 10 pulse.
2. Close the rear center safety cover and
upper cover.
3. Turn on the servo switch.
4. Press .
• The “Machine adjustment menu” screen
reappears.
3Y3C-E-MMD01-A09-02
To the next page
OFF ( )
ON ( )
SERVO
3Y3C-104P
3Y3C-EEn-MaAi-003
3Y3C-EEn-MaAi-005
3Y3C-AG01