CM88Maintenace1.pdf - 第127页
Page 1-89 REGULAR MAINTENANCE 1 Changing the Consumable Parts Every 1500 to 6000 Hours 1-7-3 Changing the Oil for Indexing Device [3000 Hours (500 Hours at the First T ime)] The operation is carried out at the rear side …

Page 1-88
Changing the Consumable Parts Every 1500 to 6000 Hours
1-7-2 Changing the Vacuum Silicon Tube [1500 Hours]
Change the vacuum silicon tube under the elevating unit at the regular interval.
It can be removed and set easily by hand.
∗ Before starting operation, carry out “Return to
origin” on the “Machine adjustment menu”
screen. If they have already been done, this is
unnecessary.
1. Turn off the servo switch.
2. Open the rear center safety cover.
3. Change the vacuum silicon tubes.
4. Close the rear center safety cover.
5. Turn on the servo switch.
6. Move the main axis by steps, and
change the silicon tubes on other
elevating unit.
∗ Step movement of main axis
“1-4-1 Cleaning and Changing the
Nozzles”
∗ Check the operation at “Checking the vacuum
pressure at the tip of nozzle” after it.
“8. Checking the vacuum pressure at the
tip of nozzle” in “1-4-1 Cleaning and
Changing the Nozzles.”
Transfer head
Vacuum silicon tubeElevating unit
OFF ( )
ON ( )
SERVO
OFF ( )
ON ( )
SERVO
3Y3C-AG01
3Y3C-062P
3Y3C-063P
3Y3C-AI01
3Y3C-E-MMD01-A07-00

Page 1-89
REGULAR
MAINTENANCE
1
Changing the Consumable Parts Every 1500 to 6000 Hours
1-7-3
Changing the Oil for Indexing Device [3000 Hours (500 Hours at the First Time)]
The operation is carried out at the rear side of machine.
1. Turn off the power.
2. Open the rear center safety cover and
upper cover.
3. Remove the cap of filler opening.
4. Set the oil receiver under the waste
opening.
5. Remove the plug (PT 3/8) for waste
opening with a wrench.
6. Open the cock and empty the oil
receiver.
7. After casting off oil, close the cock
and plug for the waste opening.
8. Fill the oil through the filler opening.
(Oil : SYNTHESO HT220)
∗ Fill oil until it reaches to the middle of window.
9. Close the cap for the filler opening.
∗ After operation, check for oil leakage.
R
E
L
E
A
S
E
T
R
I
P
O
F
F
O
N
R
E
S
E
T
3Y3C-AI01
Cock
3Y3C-065P
3Y3C-064P
Window
Filler
opening
Waste opening
Open
Close
3Y3C-E-MMD01-A08-01

Page 1-90
Changing the Consumable Parts Every 1500 to 6000 Hours
1-7-4 Changing the Vacuum Change Valve [3000 Hours]
This section describes exchanging the vacuum change valves.
1. Turn off the power.
2. Open the front safety cover.
3. Remove the cover of main axis with a
cross screw driver.
4. Remove the yellow connector con-
nected with vacuum change valve
from the head theta motor board.
To the next page
Main axis cover
R
E
L
E
A
S
E
T
R
I
P
O
F
F
O
N
R
E
S
E
T
3Y3C-E-MMD01-A08-02
Connector
4G3C-AB01
01DHC2AA
3Y3C-066P