CM88Maintenace1.pdf - 第84页
Page 1-46 Check Every 560 Hours (Once a Month) 1-5-4 Cleaning and Greasing the Board Holder and X-Y T able Board holder is the unit for holding the board on X-Y table. X-Y table moves the board up and down according to t…

Page 1-45
REGULAR
MAINTENANCE
1
Check Every 560 Hours (Once a Month)
1-5-3 Cleaning the Chip Recognition Section
The unit is for recognizing chips in the passing and reflecting methods and checking for the devia-
tion of chips.
∗ Before starting operation, carry out “Return to
origin” and “Stage escape” on the “Machine
adjustment menu” screen. If they have already
been done, this is unnecessary.
1. Turn off the power.
2. Open the rear center safety cover.
3. Clean the top of chip recognition
camera with a soft and clean cloth.
R
E
L
E
A
S
E
T
R
I
P
O
F
F
O
N
R
E
S
E
T
Chip recognition camera
16EYC0AA
3Y3C-E-MMD01-A05-01
3Y3C-AI01

Page 1-46
Check Every 560 Hours (Once a Month)
1-5-4 Cleaning and Greasing the Board Holder and X-Y Table
Board holder is the unit for holding the board on X-Y table. X-Y table moves the board up and
down according to the thickness of chip, and moves to the mounting position, regulating the edge
of chip holder (as chip data).
1. Turn off the power.
2. Open the front safety cover.
Board holder
3. Clean the holder with vacuum clean-
ers.
∗ Remove waste or chips.
4. Clean the linear bearing or ball screw
and apply grease.
(Oil : ALBANIA 2)
1. Linear bearing
Apply grease to rail.
2. Gear
Directly apply grease to gear.
3. Ball screw
Apply grease to ball screw.
R
E
L
E
A
S
E
T
R
I
P
O
F
F
O
N
R
E
S
E
T
15ULC0AA
07JHC2AA01
3.
3.
1.
1.
3Y3C-E-MMD01-A05-02
1.
2.
X-Y table
4G3C-AB01

Page 1-47
REGULAR
MAINTENANCE
1
Check Every 560 Hours (Once a Month)
1-5-5 Checking the MR Unit
1. Check the air pressure.
∗ Tolerant range of air pressure
0.5 MPa to 0.8 MPa.
∗ If it is out of the tolerant range, adjust it with the
valve.
2. Check the water receiver.
∗ Before water receiver gets half full with water,
empty it.
M02E
WARNING
BEFORE INSPECTING PNEUMATIC EQUIPMENTS, CUT OFF THE AIR
SUPPLY AND EXHAUST AIR FROM THE EQUIPMENTS.
You will have serious injury if the residual pressure actuates the machine.
Before inspecting pneumatic equipment, cut off the air supply and exhaust the air from the equipment.
Switch OFF the power.
Valve
Pressure gauge
Water receiver
3Y3C-002P
3Y3C-E-MMD01-A05-03
1. Unlock
2. Adjust
3. Lock
Valve operation