CM88Maintenace1.pdf - 第88页

Page 1-50 Check Every 560 Hours (Once a Month) 1-5-7 Cleaning the Feeder T able This unit is for positioning and fixing the tape feeder . W aste tape here may cause bad fixing when setting the tape feeder and so shift th…

100%1 / 166
Page 1-49
REGULAR
MAINTENANCE
1
erusserP
)N(
noitcelfeD
)mm(
1tleB5.627± 1
2tleB6.225.2 ± 5.0
3tleB6.226± 1
Check Every 560 Hours (Once a Month)
5. Check for the looseness of belt.
Add pressure (F) to the center of span between
two pulleys and the rear side of belt, and check
the deflection (δ) of belt.
Timing belt and pulley viewed from the rear side of machine
Belt 1
Belt 3
Belt 2
4G3C-AD01
3Y3C-056TE
Belt 1
Belt 3 Belt 2
3Y3C-087E
3Y3C-088E 3Y3C-089E
3Y3C-E-MMD01-A05-03
δ
F
δ
F
δ
F
Page 1-50
Check Every 560 Hours (Once a Month)
1-5-7 Cleaning the Feeder Table
This unit is for positioning and fixing the tape feeder. Waste tape here may cause bad fixing when
setting the tape feeder and so shift the chip pickup position to worsen the pickup fault rate.
1. Turn off the power.
2. Open the rear safety cover.
3. Clean the feeder table.
R
E
L
E
A
S
E
T
R
I
P
O
F
F
O
N
R
E
S
E
T
3Y3C-AI01
Feeder table
3Y3C-043P
3Y3C-E-MMD01-A05-01
Page 1-51
REGULAR
MAINTENANCE
1
Check Every 560 Hours (Once a Month)
1-5-8 Cleaning and Greasing the Feeder Drive Axis
This unit is for moving the feeder table by the servo motor.
1. Turn off the power.
2. Open the rear safety cover.
3. Clean the linear bearing and ball
screw, and apply grease.
(Oil : ALBANIA 2)
a. Linear bearing
Apply grease rail with spatula.
b. Ball screw
Grease nut through grease nipple (2 points).
c. Linear bearing
Grease through the grease nipple (4 points) of
linear bearing slider.
R
E
L
E
A
S
E
T
R
I
P
O
F
F
O
N
R
E
S
E
T
3Y3C-AI01
3Y3C-044P
3Y3C-045P
a.
3Y3C-E-MMD01-A05-01
07JGC2AA
c.
b.