CM88Maintenace1.pdf - 第134页
Page 1-96 Changing the Consumable Parts Every 1500 to 6000 Hours 2 . Changing nozzle extension claws Change claws at first and adjust position. 1 . Loosen the bolts (M3) with a hexago- nal wrench and change the nozzle ex…

Page 1-95
REGULAR
MAINTENANCE
1
Changing the Consumable Parts Every 1500 to 6000 Hours
8. Turn off the servo switch.
9. Open the rear center safety cover.
10. Rotate the main axis motor once in
the right direction, and adjust it close
to 0 again, as 0. 1. 2. 3... 998. 999. 0.
∗ Adjust it within 0 ± 10 pulse.
∗ Adjust the encoder origin.
11. Press twice.
• The “Main menu” screen reappears.
3Y3C-E-MMD01-A09-03
OFF ( )
ON ( )
SERVO
3Y3C-AI01
Reverse rotation
3Y3C-113P
3Y3C-EEn-MaAi-003
Right rotation

Page 1-96
Changing the Consumable Parts Every 1500 to 6000 Hours
2. Changing nozzle extension claws
Change claws at first and adjust position.
1. Loosen the bolts (M3) with a hexago-
nal wrench and change the nozzle
extension claws.
∗ Set the nozzle extension claw inner as pos-
sible, not to contact with the elevating unit, and
make space between the claw and the nozzle
stopper of elevating unit.
3Y3C-E-MMD01-A09-02
Bolt
3Y3C-069P
3Y3C-178E

Page 1-97
REGULAR
MAINTENANCE
1
3Y3C-E-MMD01-A09-02
OFF ( )
ON ( )
SERVO
3Y3C-AG01
To the next page
Nozzle Extend
Prohibit
Nozzle Extend
Permission
3Y3C-EEn-MaOc-001
2
1
Changing the Consumable Parts Every 1500 to 6000 Hours
3.
Adjusting the nozzle loosening lever
(Adjusting the one for CM88C is unnecessary.)
1. Close the rear center safety cover.
2. Turn on the servo switch.
3. Press
Machine
adjust
.
• The “Machine adjustment menu” screen
appears.
4. Press Output check .
• The “Output check” screen appears.
5. Press
UNLOCK
and .
• Change it to .
6. Press .
• The “Machine adjustment menu” screen
reappears.
3Y3C-EEn-Ma-001