CM88Maintenace1.pdf - 第105页

Page 1-67 REGULAR MAINTENANCE 1 Check Every 1000 Hours (Once T wo Months) 4 . Head exchange teaching NOTICE After removing and setting the transfer heads, make sure of carrying out “Head exchange teach.” Not doing it may…

100%1 / 166
Page 1-66
Check Every 1000 Hours (Once Two Months)
11. Press
UNLOCK
and Main axis step .
Main axis moves by steps.
12. After that, repeat the procedures 1. to
11. and set all transfer heads.
13. Press Nozl set chk .
Procedures of nozzle setting
“1-4-1 Cleaning and Changing the Nozzles”
Continue the operation to “Head exchange
teach.”
Main axis
3Y3C-143E
Rear side
3Y3C-E-MMD01-A06-02
Page 1-67
REGULAR
MAINTENANCE
1
Check Every 1000 Hours (Once Two Months)
4. Head exchange teaching
NOTICE
After removing and setting the transfer heads, make sure of carrying out “Head
exchange teach.” Not doing it may cause bad pickup.
1. Press Head exchange teach .
The message to check appears.
2. Press Yes .
Machine parameter teaching required after
removing and setting heads is automatically
carried out.
After “Head exchange teach,” the “Head
mainte” screen reappears.
3Y3C-E-MMD01-A06-02
Page 1-68
Check Every 1000 Hours (Once Two Months)
5. Checking the machine parameter after teaching (data check)
After “Head exchange teach,” check that machine parameter is within the tolerant range.
1. Press .
The “Machine mainte menu” screen appears.
2. Press .
The “Machine parameter menu” screen ap-
pears.
3. Press Data check .
The message “Mach prmtr data normal”
appears.
If some trouble is displayed, carry out “Nozzle
exchange teach” again, after checking that
item.
3Y3C-E-MMD01-A06-03
3Y3C-EEn-MpMm-001
3Y3C-EEn-MpMmHm-001