CM88Maintenace1.pdf - 第65页
Page 1-27 REGULAR MAINTENANCE 1 3Y3C-E-MMD01-A04-03 Check Every 140 Hours (Once a Week) Operating procedure Index station and transfer head H 11 2 3 3Y3C-139E T ransfer head Index station Main axis Front side of machine …

Page 1-26
3Y3C-E-MMD01-A04-01
1-4 Check Every 140 Hours (Once a Week)
1-4-1 Cleaning and Changing the Nozzles
Nozzle maintenance is described. Maintenance is mainly carried out on the rear side.
NOTICE
• As for maintenance only for the nozzle, carry out it without removing the trans-
fer head.
• Do not apply lubricating oil to the nozzle. Something adhered deteriorates the
movement of it.
• After cleaning and changing the nozzles, make sure of practicing “Nozzle
change teach.” Not doing it makes bad pickup.
∗ This section describes only the standard nozzle. For an optional nozzle, refer to “1-5-2 Nozzle
Specifications” in Operating Manual (for Engineers).
To remove and set nozzles for cleaning and changing properly, this section describes removing and
setting the same types of nozzle with all transfer heads.
Nozzle setting
(Viewed from the top)
Big nozzle
1005
3216
2125 1608
3Y3C-042E
1
2
3
4
5
Nozzle Name
1005
16083216
Big
Shape
Pad
Recognition
types
Through Through /reflex
2125
Through
Through
Applicable
components
TAN-D
Aluminum C,D
SOP
SOJ
PLCC
1005
1608
SS-Mini Tr
SS-Mini Di
S-Mini Tr
S-Mini Di
Melf (
φ
1 to 1.5)
2125
Mini Tr
Mini Di
Melf (
φ
2.2)
3216
3225
TAN-A,B,C
Mini-P Tr
Aluminum A,B
φ
0.5
φ
0.6
φ
0.7
φ
0.9
φ
0.9
φ
1.3
φ
1.4
φ
1.8
φ
2.5
φ
4
φ
1.5
φ
3
3Y3C-036E
3Y3C-037E
3Y3C-038E
3Y3C-040E
3Y3C-041E
Through
Nozzle position
Nozzle Position
1
2 3 4 5

Page 1-27
REGULAR
MAINTENANCE
1
3Y3C-E-MMD01-A04-03
Check Every 140 Hours (Once a Week)
Operating procedure
Index station and transfer head
H
11
2
3
3Y3C-139E
Transfer head
Index station
Main axis
Front side of machine
Nozzle selection
head theta rotation
Chip mounting
NG eject air blow
Mount angle
correction
Nozzle retraction
Chip recognition
Nozzle extension
Height detection
Pickup angle head
theta rotation
Height detection
head theta rotation
Chip pickup
Rear side of machine
Elevating unit
Nozzle position
Transfer head
Head No.
Nozzle
3Y3C-140E
1. Removing nozzle
2. Cleaning and checking nozzle 3. Changing nozzles Other type of nozzle
4. Setting nozzle
5. Checking nozzle settings
6. Teaching nozzle change
7. Checking machine parameter after teaching
8. Checking vacuum pressure at nozzle tip
[CM88C-D]
Main axis
Front side of machine
Nozzle selection
head theta rotation
Chip mounting
NG eject air blow
Mount angle
correction
Nozzle retraction
Nozzle extension
Chip recognition
Height detection
Pickup angle head
theta rotation
Height detection
head theta rotation
Chip pickup
Rear side of machine
3Y3C-140E
[CM88S-M/M1/MU]

Page 1-28
3Y3C-E-MMD01-A04-03
Check Every 140 Hours (Once a Week)
1. Removing the nozzles
∗ Before starting operation, carry out “Return to
origin” and “Stage escape” on the “Machine
adjustment menu” screen. If they have already
been done, this is unnecessary.
1. Press
Machine
parameter
.
• The “Machine parameter menu” screen ap-
pears.
2. Press Machine mainte .
• The “Machine parameter menu” screen ap-
pears.
3. Press Nozzle mainte .
• The “Nozzle mainte” screen appears.
To the next page