KE-750_MS.pdf - 第183页

When exiting PS parameters answer "Yes" to "S ave Set Parameters?" and modifications to head types will be validated. When "Save Set Values?" is answered "Yes", message box request…

100%1 / 257
4.2 Head Types
Select "1/Initial set-up" then "2/Kind of Head" and the head type setting dialog will appear as follows.
(1) Setting Headings
No. Item Contents
1 Kind of Head Laser sensor types by head
(2) Method of Setting
Select items in (1) with the tuner button.
When head type is changed, return laser and Z/ -axis MS parameters and mechanism control
parameters to default. Parameters must then be reloaded.
Parameter Default Settings
MS Parameters Servo Gain
Laser Offset (Board surface height, laser height)
Laser Scaling (Scaling, Rotation center of nozzle)
Head Offset (Assembling position, laser assembling angle)
Mechanism
Control
Parameters
Z Axis Max. speed, Acceleration, Dumping wait time
Incremental data increase in Z axis for 1 pulse
Mid / high speed ratio (%)
Low / high speed ratio (%)
Permissible Y coordinates for Z descent
θ Axis Max. speed, Acceleration, Dumping wait time
Incremental data increase in θ axis for 1 pulse
Laser Preload angle
Calculated wait time
Hold off count
Algorithm replacement threshold value (11, 11 & 11, -11)
After modifying settings and selecting "Exit", message box will appear requesting return to default or
reloading.
When "OK" is selected, all modified parameters in the head types selected will return to default.
2-15
When exiting PS parameters answer "Yes" to "Save Set Parameters?" and modifications to head
types will be validated.
When "Save Set Values?" is answered "Yes", message box requesting reloading appears. If power
failure occurs, reload values.
MS parameters set at default must be reset.
Selecting "Cancel" returns to setting dialog.
2-16
4.3 Conveyor Specifications
Select "1/Initial set-up" then "3/Conveyor Specifications" and the conveyor spec setting dialog will
appear as follows.
(1) Setting Headings
No. Item Contents
1 Conveyor Type Conveyors by type
2 Conveyor Reference Surface Reference surface for the machine
3 Conveyor Direction Conveyor direction in reference to the machine
4 Board Type Boards by type
5 Max. Board Size Max. usable board size (Std. board size is X = 410mm, Y = 360mm)
(2) Method of Setting
Enter values for the items in (1) with the tuner button or directly with keyboard.
"L Board" must be selected when setting max. board size. Selecting "Std Board" is meaningless.
When changing conveyor reference surface or conveyor direction, the following MS parameters
and machine setup coordinates must be set at default.
Default Position Modified Data Conveyor Reference
Surface
Conveyor Direction Board Type
MS Parameter CAL Block Position
{
x { (Y only)
VCS Position
{
x { (Y only)
Coplanarity Position
{
x { (Y only)
ATC Position
{
x { (Y only)
CVS Position
{
x { (Y only)
Pick Point Position x x { (Y only)
Machine Setup Reference Pin Position
{ {
x
Secondary Pin Position
{ {
x
Std Edge Position
{ {
x
Parts Waste Position
{
x x
{ Default required
x Default not required
2-17