7. HMS Replacement (Optional) HMS is adjusted with the sensor and amp. Sensor and amp are always replaced simultaneously (It is not possible to change only one.) 7.1 HMS sensor replacement Laser senso r SEMS cap screw x …
6-3 Sensor Height Adjustment (Only when sensor replaced)
Refer to QA Table, Bad Mark Sensor, Sensor height.
After adjustment, enter MS parameters.
For entry refer to MS parameter operation specifications 4 - 12 - 2 Bad mark sensor offset.
1-44

7. HMS Replacement (Optional)
HMS is adjusted with the sensor and amp. Sensor and amp are always replaced simultaneously (It is not
possible to change only one.)
7.1 HMS sensor replacement
Laser senso
r
SEMS cap screw x 2
SL6042592TN
SEMS cap screw x 2
SL6030692TN
(SEMS cap screw x 2)
SL6030892TN
Fastened with cable tie
Model 750: HMS holder (750)
E3651725000
Model 760: HMS holder (760)
E3652725000
Camera bracket D
E3809725000
Fig. 3-7-1
1-45

Affixing HMS seal
Cut along dotted line as shown in diagram.
Clean affixing surface with alcohol to remove grease and affix in position shown in diagram. (Align seal
arrow with laser projector.)
Fig. 3-7-2
Laser projecto
r
Fig. 3-7-3