4.21.3 EEPROM Clear Select "4/Others" then "3/EEPROM Cl ear" and the clear inquiry dialog appears. Yes No Current data will be lost. Would you like to stop? Q004103 Inquir y No. Button Selection Proce…

100%1 / 257
(1) Relevant Data
Data Name File Name
Ver 3.XX & prior Ver 4.00 & after
MS Parameters MSP. TMP MSP. V40
Machine Coordinate Value Data MECHPOS. TMP MECHPOS. V40
Machine Setup Data SETUP. TMP SETUP. TMP
Note: Files from Vers 3. & prior (extension TMP) and Vers 4. & after (extension V40) are not
structured for mutual compatibility.
- Ver 3.XX & prior cannot open files from Ver 4.00 & after.
- Ver 4.00 & after cannot open files from Ver 3.XX & prior.
(2) Open Address
Machine executed files (extension EXE) are opened in a storing location.
2-81
4.21.3 EEPROM Clear
Select "4/Others" then "3/EEPROM Clear" and the clear inquiry dialog appears.
Yes No
Current data will be lost.
Would you like to stop?
Q004103
Inquir
y
No. Button Selection Process
1 Yes Stops total clearing of EEPROM domain. Protects currently stored data.
2 No Totally clears EEPROM domain. Currently stored data is lost.
(1) Relevant Data
Totally clears EEPROM domain
– MS Parameters
Machine Coordinate Data
Machine Setup Data
Mechanical Control Parameters
Operating Options, Units
Mark Data Base
(2) Specifications for Clear
Only clears data within the EEPROM
Has no effect on data in RAM.
In case EEPROM is accidentally cleared, save data when exiting MS parameters.
However, the only types of data that can be saved in EEPROM from MS parameter input are
MS parameters, machine coordinate value data and machine setup data. Nothing else can
be recovered.
If EEPROM is cleared without saving and power is cut, when restarted, all data from RAM is
set to default.
Default data is not saved in EEPROM. It is obtained when machine is started up.
To save default data in EEPROM, input through MS parameters.
However, the only types of data that can be saved in EEPROM from MS parameter input are
MS parameters, machine coordinate value data and machine setup data. Nothing else can
be saved.
2-82
4.21.4 VCS Version Upgrade
Select "4/Others" then "4/Upgrade VCS S/W" and the dialog for program data transfer to imaging
equipment appears.
Inquiry Cancel
Current VCS version is RR-VV-LLX STD M
It will with versions from 02-00-01D onwards
Q004057
Inquir
y
No. Button Selection Process
1 OK Executes transfer of program to imaging equipment
2 Cancel Stops execution of program transfer to imaging equipment
(1) Process Outline
When the above inquiry is answered "OK", the system file directory on the hard disk opens
<<GX3VCS.DAT>> and transfers to the imaging equipment. At this time, if the program data file
is not discovered, the following message will appear and processing stop.
OK
VCS program file waslost while opening (Code)
GX3VCS.DAT
Q004057
E004056
While program is transferring, the LCD screen will display the following message.
When message clears, data transfer is complete and the image processing equipment has
begun to enter.
While in entry processing, vision monitor is off. At this time do not try to operate.
When entry processing is completed, vision monitor displays the result.
With this, the program transfer is completed.
If power drops make sure that the transferred version appears when restarted.
2-83