KE-750_MS.pdf - 第200页

When measuring is completed, the assembling angl e is calculated from the recognition result and modified. Remove camera adjustment stage from the CAL block. Once completed, select "OK". Setting is completed. S…

100%1 / 257
Do the same as with the X axis and carry out adjustment of the measured position.
Once the reference is determined, select "OK".
Selecting "OK" causes measurement of the distance from OCC to the Y directional mark.
When measuring is completed, the measured value is displayed. From the input value and
measured value, Y directional scaling is calculated and modified.
(2) Assembling Angle
Once the reference is determined, select "OK".
Selecting "OK" causes OCC to move to assembling angle measurement position.
Monitor image when adjustment completed
With teaching, adjust the monitor cross hair cursor so that it falls near the center of the mark and
press HOD Enter key.
Anything visible besides the marks at time of measurement will make it impossible to take a correct
reading or may cause error.
Once the reference is determined, select "OK".
Selecting "OK" causes measurement of the assembling angle.
2-32
When measuring is completed, the assembling angle is calculated from the recognition result and
modified.
Remove camera adjustment stage from the CAL block.
Once completed, select "OK".
Setting is completed.
Select "OK" to return to default operation screen.
2-33
4.9.2 Sub OCC Offset
Select "2/Offset set-up" then "1/OCC", "2/Sub OCC Offset" and the sub OCC offset setting dialog will
appear as follows.
(1) Setting Items
No. Item Contents
1 Scaling Size of 1 OCC pixel (mm/pixel)
2 Mark Center (Input Value) Mark pitch for scaling measurement (Spec value 3±0.001mm) (Temporary
parameter)
3 Fixing Angle Offset value between sub OCC & main body (main body as base) (° )
4 Fixing Position Offset value from sub OCC set position (OCC std)
(2) Method of Setting
Enter values directly from keyboard or follow operating instructions to enter automatically.
Select HOD device key to enter teaching.
Use control menu to move head when it is in the way.
Select "Exit" and after verification message box appears, home return will occur.
Operating method of automatic input
Follow instructions to operate and values will automatically acquire.
c Scaling
Place camera adjustment jig onto near center of the CAL block.
Orient the camera adjustment jig under the bonding face so that the XY coordinates written on
the BOC are aligned so that the incoming direction is minus Y.
Then, place a single sheet of white paper between the camera adjustment jig and the CAL
block.
Enter the marked distance of X & Y coordinates of the camera adjustment jig and CAL block.
(Spec value is 3±0.001mm.)
2-34