KE-750_MS.pdf - 第221页

Setting is completed. Select "OK" to return to default operation screen. 2-54

100%1 / 257
(Standard VCS)
Place a Z axis height gauge on the VCS-HT jig.
Lower LAIC head bit by bit with teaching. When nozzle tip touches Z axis height gauge surface,
press HOD Entry key.
(0.3mm VCS)
Set a Z axis height gauge on the 0.3mm adaptor.
Lower LAIC head bit by bit with teaching. When nozzle tip touches Z axis height gauge surface,
press HOD Entry key.
When teaching is completed, focus offset is calculated from the obtained coordinates and
modifications made.
Once completed, select "OK".
Set VCS jig plate A in VCS-HT jig.
Use an oscilloscope to adjust focus.
Once camera focus adjustment is completed, select "OK".
Remove jig nozzle from LAIC head.
Set VCS jig plate A in VCS-HT jig.
When 0.3mm VCS is set, remove 0.3mm adaptor from VCS-HT jig.
Remove VCS-HT jig from VCS.
Once completed, select "OK".
2-53
Setting is completed.
Select "OK" to return to default operation screen.
2-54
4.13.2 VCS Camera Scaling
Select "2/Offset set-up" then "5/VCS", "2/VCS Camera Scaling" and the VCS camera scaling setting
dialog will appear as follows.
(0.3 VCS only)
(1) Setting Items
No. Item Contents
1 Scaling Size of 1 VCS camera pixel (mm/pixel)
2 Mark Center (Input Value) Mark pitch for scaling measurement (Spec value 20±0.015mm)
(Temporary parameter)
(2) Method of Setting
Select VCS unit with the tuning button of the setting unit and enter values directly with the
keyboard or follow the internal operating instructions for automatic input.
Select HOD device key to enter teaching.
Use control menu to move head if in the way.
Operating method of automatic input
Follow instructions to operate and values will automatically acquire.
(0.3 VCS only)
Set VCS-HT jig in standard VCS.
When setting 0.3mm VCS, set a 0.3mm adaptor in VCS-HT jig.
Set VCS jig plate B in VCS-HT jig so measurement can be taken in the X direction.
Enter mark pitch of jig in X & Y directions. (Spec value 20 0.015mm.)
Once completed, select "OK".
When "OK" is selected, X direction mark pitch is measured by VCS.
2-55