KE-750_MS.pdf - 第50页

6-2 Amp Replacement Bad mark senso r cable assy E95747250A0 SEMS cap scre w SL4030581SC Bad mark senso r accessory (Supplied) Head top plate E2502725000 Fig. 3-6-3 Amp settings (Preset at factory. No adjustment necessary…

100%1 / 257
6. Bad Mark Sensor Replacement
6-1 Sensor replacement
(Supplied
with fiber)
Inner toothed
washe
r
Hex nut
BM lens holde
r
E3291725000
SEMS cap screw x 2
SL6030692TN
Hex nut
(Supplied
with fiber)
Fibe
r
To amp
Main OCC
Camera bracket D
E3809725000
Fig. 3-6-1
Using the nut and washer supplied, fasten fiber to the dimension shown at right and attach zoom head.
Fig. 3-6-2
1-42
6-2 Amp Replacement
Bad mark senso
r
cable assy
E95747250A0
SEMS cap scre
w
SL4030581SC
Bad mark senso
r
accessory (Supplied)
Head top plate
E2502725000
Fig. 3-6-3
Amp settings (Preset at factory. No adjustment necessary.)
Mode switch -> AUTO
Operation mode switch -> L. ON
Output timer switch -> NORMAL
Set buttonSurplus display?? displayReceptor level display Set display
(red LED)(green LED)(red LED)(green LED)
Fig. 3-6-4
1-43
6-3 Sensor Height Adjustment (Only when sensor replaced)
Refer to QA Table, Bad Mark Sensor, Sensor height.
After adjustment, enter MS parameters.
For entry refer to MS parameter operation specifications 4 - 12 - 2 Bad mark sensor offset.
1-44