KE-750_MS.pdf - 第229页
4.13.5 VCS Common Parameters Select "2/Offset set-up" then "5/VCS", "7/C ontrol parameters for VCS" and the VCS common parameter setting dialog will appear as follows. (1) Setting Items No. …

Setting is completed.
Select "OK" to return to default operation screen.
2-61

4.13.5 VCS Common Parameters
Select "2/Offset set-up" then "5/VCS", "7/Control parameters for VCS" and the VCS common
parameter setting dialog will appear as follows.
(1) Setting Items
No. Item Contents
1 Binary Threshold Value Std VCS Standard VCS binary threshold value
2 Binary Threshold Value 0.3mm VCS 0.3mm VCS binary threshold value
3 Position of Measuring Lines Position of measuring lines
4 No. of Measuring Lines Number of measuring lines
5 DOG Filter Size Size of DOG filter
6 DOG Filter Threshold Value (Side) Filter threshold value in side direction
7 DOG Filter Threshold Value (Length) Filter threshold value in length direction
(2) Method of Setting
– Input values directly from keyboard.
– There are 16 types of DOG filter (0~15) for component form recognition. The input field is
divided 0~7 and 8~15. Use "Pg Up" and "Pg Dn" keys to move between fields.
– When F10 key is pressed, binary threshold values are automatically entered.
– Focus position when F10 key is selected distiguishes setting VCS.
Standard VCS is set to focus binary threshold values in standard VCS.
0.3mm VCS is set to focus binary threshold values in standard 0.3mm VCS.
2-62

– Operating method of automatic input
Follow instructions to operate and values will automatically acquire.
Set #203 nozzle in LAIC head.
Once completed, select "OK".
When "OK" is selected, nozzle moves to setting VCS.
– Contents of Measurement
(1) The binary threshold value is automatically measured with nozzle.
Once measurement is completed, result is displayed.
Remove #203 nozzle from LAIC head.
Once completed, select "OK" or "Cancel".
When "OK" is selected, the binary threshold values of setting VCS are modified and operating
screen clears.
When "Cancel" is selected, the binary threshold values of setting VCS are not modified and
operating screen clears.
2-63