4.9.2 Sub OCC Offset Select "2/Offset set-up" then "1/OCC", "2/Sub OCC Offset" and the sub OCC offset setting dialog will appear as follows. (1) Setting Items No. Item Contents 1 Scaling Siz…

When measuring is completed, the assembling angle is calculated from the recognition result and
modified.
Remove camera adjustment stage from the CAL block.
Once completed, select "OK".
Setting is completed.
Select "OK" to return to default operation screen.
2-33

4.9.2 Sub OCC Offset
Select "2/Offset set-up" then "1/OCC", "2/Sub OCC Offset" and the sub OCC offset setting dialog will
appear as follows.
(1) Setting Items
No. Item Contents
1 Scaling Size of 1 OCC pixel (mm/pixel)
2 Mark Center (Input Value) Mark pitch for scaling measurement (Spec value 3±0.001mm) (Temporary
parameter)
3 Fixing Angle Offset value between sub OCC & main body (main body as base) (° )
4 Fixing Position Offset value from sub OCC set position (OCC std)
(2) Method of Setting
– Enter values directly from keyboard or follow operating instructions to enter automatically.
– Select HOD device key to enter teaching.
– Use control menu to move head when it is in the way.
– Select "Exit" and after verification message box appears, home return will occur.
– Operating method of automatic input
Follow instructions to operate and values will automatically acquire.
c Scaling
Place camera adjustment jig onto near center of the CAL block.
Orient the camera adjustment jig under the bonding face so that the XY coordinates written on
the BOC are aligned so that the incoming direction is minus Y.
Then, place a single sheet of white paper between the camera adjustment jig and the CAL
block.
Enter the marked distance of X & Y coordinates of the camera adjustment jig and CAL block.
(Spec value is 3±0.001mm.)
2-34

Once completed, select "OK" and sub OCC will move to X axis scaling position.
Monitor image when adjustment completed
With teaching adjust the monitor cross hair cursor so that it falls near the center of the 2 marks
and press HOD Enter key.
If no adjustment is needed, teaching is not required.
Should any dust be visible at this time, wipe the camera adjust jig thoroughly so that only the
marks are visible.
Anything visible besides the marks at time of measurement may make it impossible to take a
correct reading or may cause error.
Once completed, select "OK".
Selecting "OK" causes measurement of the distance from sub OCC to the X directional mark.
When measurement is completed, the measured value is displayed. From the input value and
measured value, X directional scaling is calculated and modified.
Once completed, select "OK".
Select "OK" and the sub OCC will move to the Y axis scaling position.
Monitor image when adjustment completed
2-35