ForteMAXDispensingSystemAddendum Installation and Setup
© 2023 Nordson Corporation 19
13. Replace the right dovetail assembly and loosely tighten the dovetail mounting screw
(Figure 3-14).
> Do not tighten the dovetail mounting screw all the way. The mounting screw will be
tightened after both valves have been installed and the distance between the valves
has been verified.
Item Description
1 Dovetail Mounting Screw
2 Dovetail Side Screw
3 Right Dovetail Assembly
4 Standard Slide Bracket
Figure 3-14 Installing the Right Dovetail Assembly
14. Adjust the conveyor width to accommodate the board size.
15. Adjust the lift tables and clamps so that the board does not move during programming.
16. Go to Step 8 to Home the Forte MAX bracket.
17. Install Valve 1 into the Valve 1 dovetail bracket.
18. Install Valve 2 into the Valve 2 dovetail bracket and tighten the dovetail side screw to
secure the valve (Figure 3-14).
> The dovetail mounting screw (top screw) should be loose so the dovetail can be moved
for final pitch adjustment.
4
3
1
2

ForteMAXDispensingSystemAddendum Installation and Setup
20 © 2023 Nordson Corporation
19. Using a digital caliper, measure the width of Valve 1 (Figure 3-15).
Figure 3-15 Measure Width of Valve 1
20. Zero the caliper and set the caliper to the intended pitch.
> In this example, the intended pitch is 50 mm.
> The caliper is now set to include Valve 1 and the pitch between Valve 1 and Valve 2.
21. Move Valve 2 dovetail bracket until distance between the Valve 1 and Valve 2 center lines
match the pitch on the caliper (Figure 3-16).
Figure 3-16 Set Caliper to Intended Pitch

ForteMAXDispensingSystemAddendum Installation and Setup
© 2023 Nordson Corporation 21
22. Once the distance has been verified, carefully tighten the Valve 2 dovetail mounting screw
(top screw) so that the Valve 2 position does not shift (Figure 3-14).
> Tightening the screw can cause a minor shift in the Valve 2 position. Remeasure and
readjust the position if necessary.
23. Connect the valve electrical and pneumatic connections to the dispensing system bulkhead
(Figure 3-17).
Figure 3-17 Forte MAX Dispensing System Bulkhead
24. If there is a large gap between the V1 and V2 nozzle tip, perform the following steps to
adjust V1 so that the V1 and V2 nozzle tips are at the same height.
a.
Auto Dual Simultaneous Dispensing
1) Select the Maintenance button on the Navigation Panel.
2) Select Motion > Auto Dual Head Motion (Figure 3-18).
3) Place the dispense head in a Safe Z position.
4) Enter 10 mm under Z-Axis and click Move.
Figure 3-18 Valve 1 Adjustment – Dual Simultaneous