© 2023 Nordson Corpo ration 63 6 Parts Replacement 6.1 Overview This sect ion in cludes parts replacement instr uctions and information for ordering re commended spares and replacement parts for your dispensi ng system. …

100%1 / 76
ForteMAXDispensingSystemAddendum Maintenance
62 © 2023 Nordson Corporation
21. Loosely install the slide bracket in the position noted during removal.
> The four (4) screws should be loose.
22. While applying a slight downward pressure on the slide bracket so that it is resting, and in
alignment with the alignment length in the back, torque the four (4) screws to
1.3 Nm (12 in-lbs).
23. Power on the dispensing system. Refer to the Forte Dispensing System Installation,
Operations, and Maintenance Manual if necessary.
24. Start the Canvas dispensing software. Refer to the Canvas Dispensing Software User
Guide if necessary.
25. After the machine has homed, open the dispensing system hatch and lightly grease the top
half of the Z-axis lead screw with the Super Lube Synthetic Grease (Figure 5-14).
Item Description
1 Z-Axis Lead Screw
Figure 5-14 Lubricating the Z-Axis Lead Screw
26. Reinstall both valves. Refer to the applicable valve manual for installation procedures.
27. Perform a valve offsets procedure. Refer to the Canvas Dispensing Software User Guide if
necessary.
1
© 2023 Nordson Corporation 63
6 Parts Replacement
6.1 Overview
This section includes parts replacement instructions and information for ordering recommended spares
and replacement parts for your dispensing system. This section contains the following procedures:
P
art
s Or
deri
ng Infor
m
atio
n
Unpackin
g and Insp
ect
in
g Re
placemen
t
P
arts
Warran
ty
Cleanin
g and Inspe
ction
Credi
t and
E
x
chang
e
s
S
p
a
r
e
P
a
r
t
s
L
i
s
t
Re
cord
Ke
eping
WARNING!
Parts replacement should only be performed by a trained service technician.
Asymtek assumes no liability for personal injury or property damage that may
occur as a result of spare parts being replaced by a non-certified technician.
6.2 Safety First
Operation of the dispensing system involves heat, air pressure, electrical power, mechanical devices, and
the use of hazardous materials. It is essential that every person servicing or operating the dispensing
system fully understands all hazards, risks, and safety precautions. Refer to Section 2 – Safety in this
manual and to the Forte Dispensing System Installation, Operations, and Maintenance Manual for
important safety information.
WARNING!
Perform a service shutdown before replacing parts. Servicing electrical,
pneumatic, or hydraulic components or assemblies that make de-energizing the
whole system impractical, should only be performed by trained personnel. There
should always be a second person present when servicing a system under power.
WARNING!
DO NOT hot swap connections when working with electrical and pneumatic power
supplies. Turn the main circuit break off before disconnecting the external power
plug from the facility.
ForteMAXDispensingSystemAddendum Parts Replacement
64 © 2023 Nordson Corporation
6.3 Parts Ordering Information
6.3.1 Placing Your Order
Customers can order spare parts by contacting Asymtek Customer Service. Contact information is listed
at the front of this manual. Spare parts can also be ordered online through our Internet Web Store. To set
up a web store account, send an email to americas.es.cs@nordson.com.
?
NOTE
This section does not include the removal and replacement of dispensing valve
components. Refer to the applicable valve manual for instructions.
When ordering parts, be prepared to provide the following information:
Your C
ompany N
ame
Billing Addr
ess
S
hip
ping A
dd
ress
Part
Number an
d Des
cr
i
ption
Purchas
e Or
der
Num
ber
Quantity
Dispensing System Serial Number
(foun
d o
n
back
panel)
Shipping Instructions with Collect Account
Number
6.3.2 Shipping Instructions
When ordering parts, specify which carrier you prefer to use and provide your shipping account number. If
no instructions are received, Asymtek will determine the best shipping method and items will be shipped
prepaid with the shipping charge added to the invoice.
6.4 Warranty
Contact Asymtek Technical Support for any warranty issues pertaining to spare parts. Wear items and
consumables are covered under warranty against manufacturer defect only. Expected lifetimes for these
parts will vary based upon application and use.
Consumable parts are generally considered as parts that are replaced on a frequency of > 1 per calendar
year under expected regular usage. In most cases, these parts are “wetted parts” that make contact with
the dispensed fluid. Wear items are those items that have been identified to have limited life expectancy
(less than 5 years) but are not considered consumables. Wear items are often highly application
dependent, high user-touch, or adjusted parts.
6.5 Credit and Exchanges
Contact Asymtek Customer Service for credit or exchanges of recommended spare parts or refurbished
components (components restored to original specifications but not sold as new).
6.5.1 Return Material Authorization
Contact Asymtek Technical Support to obtain a Return Material Authorization (RMA) before returning any
parts.
?
NOTE
Find your local Technical Support contact on the Asymtek web page,
www.nordsonasymtek.com.
6.6 Record Keeping
The type of service performed should be recorded in the dispensing system maintenance records. Dates,
part numbers/serial numbers of replaced parts, names of technicians, and other pertinent data should be
recorded.