Forte Max Manual.pdf - 第25页
ForteMAXDispensingSystemAddendum Installation an d Setup © 2023 Nordson Corporation 21 22. Once the distance ha s been verified, car efully tighten the Valve 2 dovetail mounting screw (top screw) so that the Valve 2 …

ForteMAXDispensingSystemAddendum Installation and Setup
20 © 2023 Nordson Corporation
19. Using a digital caliper, measure the width of Valve 1 (Figure 3-15).
Figure 3-15 Measure Width of Valve 1
20. Zero the caliper and set the caliper to the intended pitch.
> In this example, the intended pitch is 50 mm.
> The caliper is now set to include Valve 1 and the pitch between Valve 1 and Valve 2.
21. Move Valve 2 dovetail bracket until distance between the Valve 1 and Valve 2 center lines
match the pitch on the caliper (Figure 3-16).
Figure 3-16 Set Caliper to Intended Pitch

ForteMAXDispensingSystemAddendum Installation and Setup
© 2023 Nordson Corporation 21
22. Once the distance has been verified, carefully tighten the Valve 2 dovetail mounting screw
(top screw) so that the Valve 2 position does not shift (Figure 3-14).
> Tightening the screw can cause a minor shift in the Valve 2 position. Remeasure and
readjust the position if necessary.
23. Connect the valve electrical and pneumatic connections to the dispensing system bulkhead
(Figure 3-17).
Figure 3-17 Forte MAX Dispensing System Bulkhead
24. If there is a large gap between the V1 and V2 nozzle tip, perform the following steps to
adjust V1 so that the V1 and V2 nozzle tips are at the same height.
a.
Auto Dual Simultaneous Dispensing
1) Select the Maintenance button on the Navigation Panel.
2) Select Motion > Auto Dual Head Motion (Figure 3-18).
3) Place the dispense head in a Safe Z position.
4) Enter 10 mm under Z-Axis and click Move.
Figure 3-18 Valve 1 Adjustment – Dual Simultaneous

ForteMAXDispensingSystemAddendum Installation and Setup
22 © 2023 Nordson Corporation
b.
Dual Action Dispensing
1) Select the Maintenance button on the Navigation Panel.
2) Select Motion > Auto Dual Head Motion (Figure 3-19).
3) Click the Home button on the Z-Axis column.
4) Enter 10 mm in the Z-Axis column
5) Click on Move in the Z-Axis column.
Figure 3-19 Valve 1 Adjustment – Dual Toggle
c.
Move both dispense heads down so that the V1 and V2 nozzle tips are close to the
conveyor rail surface.
d.
Visually check the height of the V1 and V2 nozzle tips to see if they are at the same
height (Figure 3-20).
> Acceptable tolerance is ± 8 mm.
e.
If not, remove V1 and adjust the V1 dovetail mount position in the Z-axis until the V1
and V2 nozzle tips are at the same height.
> This step is generally only necessary if the valves are different types.
Figure 3-20 Valves Installed