00197004-04_UM_X-Serie-S_EN.pdf - 第101页
User manual SIPLACE X-Series 2 Operational safety From software version 706.1 SP1 Version 10/2014 2.9 Energy state of the machine afte r switching off at the main power switch 101 2.9 Energy st ate of the machine af ter …

2 Operational safety User manual SIPLACE X-Series
2.8 Disabling the compressed air supply and discharging the pressure From software version 706.1 SP1 Version 10/2014
100
2
Fig. 2.8 - 1 Compressed air unit on the machine
Legend for fig. 2.8 - 1
(1) Manometer for the machine component supply pressure
Target pressure: 0.5 ± 0.025 MPa, 5 ± 0.25 bar (display range 0 - 1.0 MPa, 0 - 10 bar)
(2) Manometer for supply pressure of gantries 1 to 4
Target pressure: 0.46 ± 0.01 MPa, 4.6 ± 0.1 bar (display range 0 - 1.0 MPa, 0 - 10 bar)
(3) Manometer for inlet pressure
Target pressure: 0.5 - 1.0 MPa, 5 - 10 bar (display range: 0 - 1.0 MPa, 0 - 10 bar)
(4) Stop valve in the "OPEN" position
(5) Compressed air filter
(6) Compressed air connection
2
WARNING
Risk of injuries!
Risk of injuries from pressurized compressed air lines.
NEVER detach compressed air lines while they are still pressurized.
(6)
(1)
(2)
(3)
(5)
(4)

User manual SIPLACE X-Series 2 Operational safety
From software version 706.1 SP1 Version 10/2014 2.9 Energy state of the machine after switching off at the main power switch
101
2.9 Energy state of the machine after switching off at the
main power switch
2
Fig. 2.9 - 1 Position of power supply on the machine (example of SIPLACE X2 S / X3 S / X4 S shown)
2
2
(1) Main switch
DANGER
Dangerous voltage levels!
The machine is supplied with 3 x 200 V~, 3 x 208 V~, 3 x 220 V~, 3 x 230 V~,
3 x 380 V~, 3 x 400 V~ or 3 x 415 V~ ± 5 %, 50/60 Hz mains voltage. This means that
some parts of the system carry potentially lethal voltages - even when switched off at the
main power switch.
Incorrect handling of this machine can therefore result in death or severe injury or con-
siderable damage to equipment.
Always follow the applicable accident prevention and DIN regulations (particularly
EN 60204, part 1 or IEC 60204, part 1) and the applicable regulations in your own
country.
The covers over the power supply unit may ONLY be opened by appropriately qual-
ified and trained personnel.
(1)

2 Operational safety User manual SIPLACE X-Series
2.9 Energy state of the machine after switching off at the main power switch From software version 706.1 SP1 Version 10/2014
102
2.9.1 Machine switched off at the main switch, but still connected
2
2
Fig. 2.9 - 2 Power supply unit, front view
(1) Service socket (X102)
(2) Mains connection terminals (X100)
(3) Main switch (Q1)
DANGER
Lethal voltages!
Incorrect handling of the machine can therefore result in death or severe injury or consid-
erable damage to equipment.
The following components still carry potentially lethal voltages even if the main power
switch is switched off:
– Mains connection terminals in the transformer unit L1, L2 and L3 of main switch Q1
– Service socket X98
– Service socket X102 with F1 automatic circuit breaker switched on.
– The color of all individual wires, which still carry potentially lethal voltages even if the
main power switch is switched off, is brown.
(3)
(1)
(2)