120
3.1.11 Component supply
3
Tape reel diameter
Standard
Maximum
to 432 mm (17“)
483 mm (19“)
Max. component supply
4 component trolleys X on the SIPLACE X2 S / X3 S / X4 S
4 component trolleys X on the SIPLACE X4i S
4 component trolleys X on the SIPLACE X4 S micron
4 component trolleys X on the SIPLACE X4i S micron
160 feeder modules, each with 8 mm X
148 feeder modules, each with 8 mm X
160 feeder modules, each with 8 mm X
148 feeder modules, each with 8 mm X
Component trolley changeover time < 1 minute
Feeder module types (SIPLACE X) with adapter Tape feeder modules, reject conveyors,
stick magazine and label presenters.
User manual SIPLACE X-Series 3 Technical data and assemblies
From software version 706.1 SP1 Version 10/2014 3.2 Ambient conditions and connection values
121
3.2 Ambient conditions and connection values
3.2.1 Ambient conditions for packaging, transportation and storage
3
3.2.2 Ambient conditions for machine operation
3
Temperature range Between -25°C and 55°C
Atmospheric humidity Up to 95%
Ambient pressure Up to 3000 m height without pressure equalization
Room temperature Between 15°C and 35°C
Atmospheric humidity 30% to 75%
(on average not higher than 45%, so that there is no risk of
condensation on the machine.)
Ambient pressure > 750 mbar (corresponds to 2500 m above mean sea level)
3 Technical data and assemblies User manual SIPLACE X-Series
3.2 Ambient conditions and connection values From software version 706.1 SP1 Version 10/2014
122
3.2.3 Electrical ratings and energy consumption
3
Energy consumption SIPLACE X2 S
With a vacuum pump Without vacuum pumps
*a
Main power sup-
ply
3/PE ~ 200 V
3/PE ~ 220 V
3/N/PE ~ 208/120 V
3/N/PE ~ 220/127 V
3/N/PE ~ 230/133 V
3/N/PE ~ 380/220 V
3/N/PE ~ 400/230 V
3/N/PE ~ 415/240 V
3/PE ~ 200 V
3/PE ~ 220 V
3/N/PE ~ 208/120 V
3/N/PE ~ 220/127 V
3/N/PE ~ 230/133 V
3/N/PE ~ 380/220 V
3/N/PE ~ 400/230 V
3/N/PE ~ 415/240 V
Frequency 50/60 Hz 50/60 Hz
Rated current 5,9 A
11.8 A (USA)
4,7 A
8.9 A (USA)
Performance 2.8 kW
2.9 kW (USA)
2.0 kW
2.0 kW (USA)
Mains power
connection
Cable 5 x 4 mm² 3 x 20 A (3 x 200 V~ / 208 V~ / 220 V~/ 230 V ~)
Cable 5 x 4 mm² with CEKON connector 3 x 16 A (3 x 380 V~ / 400 V~ / 415 V~)
Fuse 3 x16 A characteristic C
*b
*c
3 x20 A characteristic C (USA)
3 x16 A characteristic C
b c
3 x20 A characteristic C (USA)
Energy consumption SIPLACE X3 S
With a vacuum pump With two vacuum pumps Without vacuum pumps
a
Main power sup-
ply
3/PE ~ 200 V
3/PE ~ 220 V
3/N/PE ~ 208/120 V
3/N/PE ~ 220/127 V
3/N/PE ~ 230/133 V
3/N/PE ~ 380/220 V
3/N/PE ~ 400/230 V
3/N/PE ~ 415/240 V
3/PE ~ 200 V
3/PE ~ 220 V
3/N/PE ~ 208/120 V
3/N/PE ~ 220/127 V
3/N/PE ~ 230/133 V
3/N/PE ~ 380/220 V
3/N/PE ~ 400/230 V
3/N/PE ~ 415/240 V
3/PE ~ 200 V
3/PE ~ 220 V
3/N/PE ~ 208/120 V
3/N/PE ~ 220/127 V
3/N/PE ~ 230/133 V
3/N/PE ~ 380/220 V
3/N/PE ~ 400/230 V
3/N/PE ~ 415/240 V
Frequency 50/60 Hz 50/60 Hz 50/60 Hz
Rated current 5,9 A
11.8 A (USA)
7,1 A
14.7 A (USA)
4,7 A
8.9 A (USA)
Performance 2.8 kW
2.9 kW (USA)
3.5 kW
3.8 kW (USA)
2.0 kW
2.0 kW (USA)
Mains power
connection
Cable 5 x 4 mm² 3 x 20 A (3 x 200 V~ / 208 V~ / 220 V~/ 230 V ~)
Cable 5 x 4 mm² with CEKON connector 3 x 16 A (3 x 380 V~ / 400 V~ / 415 V~)
Fuse 3 x16 A characteristic C
b c
3 x20 A characteristic C (USA)
3 x16 A characteristic C
b
3 x20 A characteristic C
c
3 x20 A characteristic C (USA)
3 x16 A characteristic C
b c
3 x20 A characteristic C (USA)
*)a Optional
*)b For voltages 380 V/400 V/415 V
*)c For voltages 200 V/208 V/220 V/230 V