00192662-01.pdf - 第202页
5 Single Functions User Manual SIPLACE F5/F5 HM 5.2 Single functions, Gantry Software version SR.407.x x 01/2001 US E dition 202 5.2.7.2 Functions Lock. op./ close 5 T o be a ble to fill the m agazi ne man ually , you m …
User Manual SIPLACE F5/F5 HM 5 Single Functions
Software version SR.407.xx 01/2001 US Edition 5.2 Single functions, Gantry
201
5.2.7.1 General comments
In the "Nozzle changer configuration revolver head" screen there are functions which allow you to
adjust and confirm the nozzle configuration for the individual magazines in the nozzle changer.
Click on the appropriate button to carry out the required function.
The nozzle changer configuration is displayed in the table in the display.
5
Conditions for changing the set-up of the nozzle changer
Remember the following points when changing the set-up: 5
– The magazines may only be filled when all nozzles on the Collect&Place head have been re-
turned to their magazines.
– The magazines for type 7xx or 8xx nozzles are different.
– Only nozzles of type 7xx or 8xx can be set up in a single magazine. They must not be mixed.
– The maximum number of nozzles per magazine is 6.
– The maximum number of magazines on a nozzle changer is 5.
– The magazines must be filled outside the machine and must only ever be changed in their en-
tirety.
– To remove and load nozzles you must open the lock. Once you have finished, you must then
close the lock again.
Meaning of the entries in the table in the display
– Magazine
Number of the magazine
– Garage
Number of the nozzle holder
– Number
Number of nozzles in the magazine
– Actual
Type of nozzles currently in the magazine
– Preset
If the type of nozzle currently in the magazine is not the same as shown in this column, then it
is to be changed
– To change
An arrow ( <== ) in this column indicates that the nozzle type currently in the magazine
("Actual" column) must be changed for the nozzle type shown in the "Preset" column.
5 Single Functions User Manual SIPLACE F5/F5 HM
5.2 Single functions, Gantry Software version SR.407.xx 01/2001 US Edition
202
5.2.7.2 Functions
Lock. op./close 5
To be able to fill the magazine manually, you must use this function to open the lock (locking
plate) on the nozzle changer and close it afterwards.
Å Click the Lock. op./close button.
The magazine locking plate is opened.
Å Click the Lock. op./close button.
The magazine locking plate is closed again.
Refill 5
This function allows you to refill the magazine with new nozzles of the type already in use without
changing the current setup.
During placement it can become necessary to refill individual nozzles in the magazines. This in-
volves filling the individual nozzle holders with nozzles of the type already in use. 5
The nozzle types shown in the columns "Actual" and "Preset" of the table will agree.
The number of nozzles in the appropriate nozzle holder is shown in the "Number" column (0 =
not present / 1 = present). 5
Å From the table, choose the entry for the nozzle holder in which a nozzle is to be refilled. This
line is then highlighted in light blue.
Å Click the Lock. op./close button.
Å Fill the nozzle holder with the type of nozzle which was already set up there.
Å Click the Lock. op./close button again.
Å Click the Refill button.
The inventory level of the selected nozzle holder is updated (see "Number" column).

User Manual SIPLACE F5/F5 HM 5 Single Functions
Software version SR.407.xx 01/2001 US Edition 5.2 Single functions, Gantry
203
During setup change, it may be necessary to change to a different type of nozzle in individual mag-
azines. To do this, the table shows for each nozzle holder the current nozzle configuration (Actual)
and the nozzle configuration required by the new setup (Preset).
When a nozzle is changed from the "Actual nozzle type" to the "Preset nozzle type", this operation
must be confirmed. This can either be done for all the nozzle holders in a magazine ("Confirm
magaz." function) or separately for each nozzle holder ("Confirm one nozzle" function). 5
NOTE
The magazines must always be completely filled. 5
Confirm magaz. 5
This function confirms that all nozzle holders of one magazine have been filled with nozzles of a
new type. 5
Å In the table, select any entry for a nozzle holder of the magazine in which the nozzles are to
be replaced. The line is now highlighted in light blue.
Å Click the Lock. op./close button.
Å Replace all the nozzles by nozzles of the type entered in the "Preset" column.
Å Click the Lock. op./close button again.
Å Click the Confirm one nozzle button to confirm that the nozzles in the selected nozzle holder
have been replaced. The change of is now confirmed. In the table, the arrow ( <== ) is no longer
displayed next to the entry for this nozzle holder.
5