11 Station extensions /Hardware User Manua l SIPLACE F5/F5 HM 11.9 Flux dispenser unit Software version SR. 407.xx 01/2001 US E dition 534 1 1.9.7.3 Editi ng the flux p arameter s Å Select the “ Parameters ” menu to ente…

100%1 / 596
User Manual SIPLACE F5/F5 HM 11 Station extensions /Hardware
Software version SR.407.xx 01/2001 US Edition 11.9 Flux dispenser unit
533
11
Fig. 11.9 - 8 Editing the fluxing package form list
(1) Highlight the line
(2) Edit button
(3) Input boxes
11
Å Edit the data as described for Add.
Å Click on OK to confirm your input.
Å Click on Accept to save the edited package form list.
11
311 111 211
11 Station extensions /Hardware User Manual SIPLACE F5/F5 HM
11.9 Flux dispenser unit Software version SR.407.xx 01/2001 US Edition
534
11.9.7.3 Editing the flux parameters
Å Select the Parameters menu to enter data for the fluxing process.
11
Fig. 11.9 - 9 Editing the flux parameters
11
Waiting time for the PCB conveyor 11
The time for which the PCB remains in the station until it undergoes further placement. This
ensures that the flux dries reliably, and the component cannot float away.
This time is measured from the last flip-chip component to be placed,
and can be set to between 0 and 40 seconds.
PLEASE NOTE
Setting this waiting time can have a detrimental effect on line utilization. 11
11
User Manual SIPLACE F5/F5 HM 11 Station extensions /Hardware
Software version SR.407.xx 01/2001 US Edition 11.9 Flux dispenser unit
535
11
Fig. 11.9 - 10 Rinsing / brushing station with rinsing tank
(1) Brush with retainer
(2) Rinsing / brushing station
(3) Brushing / rinsing tank
11
11
Automatic rinsing after: 11
To prevent the centering nozzle and dispensing needle from crystallizing after a long break
between flux applications, a time can be set after which the rinse cycle starts. This means
that the preset rinse cycle is carried out immediately before the next flip-chip is placed, ac-
cording on the selected placement sequence.
A rinse cycle is carried out automatically when the machine is switched on, regardless of
the set rinsing time.