00192662-01.pdf - 第63页

User Manual SIPLACE F5/F 5 HM 1 Introduction and technical data Software version SR.407.xx 01/2001 US Edition 1.13 Overview of the modules - placement heads 63 1.13.1 1 Description of the 6-s egment Collect&Place hea…

100%1 / 596
1 Introduction and technical data User Manual SIPLACE F5/F5 HM
1.13 Overview of the modules - placement heads Software version SR.407.xx 01/2001 US Edition
62
1.13.10 Structure of the 6-segment C&P head with component vision module for
flip-chips, bare dies, and standard components (DCA option)
1
Fig. 1.13 - 4 Structure of the 6-segment C&P head with component vision module
for flip-chips, bare dies, and standard components
(1) Star with 6 sleeves
(2) Motor for "Reject" valve adjustment drive
(3) Turning station
(4) DCA vision module
(5) Z axis driving mechanism
(6) Star motor
User Manual SIPLACE F5/F5 HM 1 Introduction and technical data
Software version SR.407.xx 01/2001 US Edition 1.13 Overview of the modules - placement heads
63
1.13.11 Description of the 6-segment Collect&Place head with DCA option
With the DCA vision module, the 6-segment Collect&Place head is able to optically center and
place components of the order of magnitude of 0.5mm x 0.25mm to 13mm x 13mm. The DCA
package optimizes the speed and accuracy when placing high-speed flip-chips and bare die
components. 1
1.13.12 Technical data of the 6-segment Collect&Place head with DCA option
Component dimensions
Max. height
Max. weight
0.5mm x 0.25mm to 13mm x 13mm
8.5mm
5 g
Travel of the Z axis Max. 16 mm
Programmable placement force 2.4 to 5.0 N
Max. placement rate 8,000 components/hour
Angular accuracy ± 0.225° / 3 σ, ± 0.30° / 4 σ, ± 0.45° / 6 σ
Placement accuracy of the DCA vision
module
± 45 µm / 3 σ, ± 60 µm / 4 σ, ± 90 µm / 6 σ
1 Introduction and technical data User Manual SIPLACE F5/F5 HM
1.14 Overview of the modules - vision systems Software version SR.407.xx 01/2001 US Edition
64
1.14 Overview of the modules - vision systems
Every machine has 1
a PCB vision module on the Collect&Place head,
a fine-pitch component vision module on the machine base, and
a PCB vision module on the underside of the X-axis gantry
1
The vision evaluation unit is located on the machines control unit. The component vision module
is used to 1
determine the precise position of the component at the nozzle, and
the geometry of the package form.
1
The PCB vision module uses fiducials on the PCB to determine 1
the position of the PCB,
its rotational angle,
and the PCB distortion.
Damaged PCBs or subpanels are marked with ink spots. The PCB vision module scans the ink
spots, and signals that these circuits should not be placed. 1
The PCB vision module also uses fiducials on the feeders to determine the precise component
pick-up position. This is particularly important for tiny components. 1
1.14.1 Technical data of the component vision module on the 12-segment C&P head
Max. component dimensions 0.5mm x 1.0mm to 18.7mm x 18.7mm
Component range
0402 to PLCC44
including BGA, µBGA, flip-chip, TSOP, QFP
PLCC, SO to SO32, DRAM
Minimum lead pitch 0.5 mm
Field of view 24mm x 24mm
Method of illumination Front lighting (3 levels programmable as required)