00192662-01.pdf - 第203页
User Manual SIPLAC E F5/F5 HM 5 Single Functions Software version SR.407.xx 01/2001 US Edition 5.2 Single functions, Gantry 203 During se tup change, i t may be nec essary to ch ange to a di fferent type of nozz le in in…
5 Single Functions User Manual SIPLACE F5/F5 HM
5.2 Single functions, Gantry Software version SR.407.xx 01/2001 US Edition
202
5.2.7.2 Functions
Lock. op./close 5
To be able to fill the magazine manually, you must use this function to open the lock (locking
plate) on the nozzle changer and close it afterwards.
Å Click the Lock. op./close button.
The magazine locking plate is opened.
Å Click the Lock. op./close button.
The magazine locking plate is closed again.
Refill 5
This function allows you to refill the magazine with new nozzles of the type already in use without
changing the current setup.
During placement it can become necessary to refill individual nozzles in the magazines. This in-
volves filling the individual nozzle holders with nozzles of the type already in use. 5
The nozzle types shown in the columns "Actual" and "Preset" of the table will agree.
The number of nozzles in the appropriate nozzle holder is shown in the "Number" column (0 =
not present / 1 = present). 5
Å From the table, choose the entry for the nozzle holder in which a nozzle is to be refilled. This
line is then highlighted in light blue.
Å Click the Lock. op./close button.
Å Fill the nozzle holder with the type of nozzle which was already set up there.
Å Click the Lock. op./close button again.
Å Click the Refill button.
The inventory level of the selected nozzle holder is updated (see "Number" column).

User Manual SIPLACE F5/F5 HM 5 Single Functions
Software version SR.407.xx 01/2001 US Edition 5.2 Single functions, Gantry
203
During setup change, it may be necessary to change to a different type of nozzle in individual mag-
azines. To do this, the table shows for each nozzle holder the current nozzle configuration (Actual)
and the nozzle configuration required by the new setup (Preset).
When a nozzle is changed from the "Actual nozzle type" to the "Preset nozzle type", this operation
must be confirmed. This can either be done for all the nozzle holders in a magazine ("Confirm
magaz." function) or separately for each nozzle holder ("Confirm one nozzle" function). 5
NOTE
The magazines must always be completely filled. 5
Confirm magaz. 5
This function confirms that all nozzle holders of one magazine have been filled with nozzles of a
new type. 5
Å In the table, select any entry for a nozzle holder of the magazine in which the nozzles are to
be replaced. The line is now highlighted in light blue.
Å Click the Lock. op./close button.
Å Replace all the nozzles by nozzles of the type entered in the "Preset" column.
Å Click the Lock. op./close button again.
Å Click the Confirm one nozzle button to confirm that the nozzles in the selected nozzle holder
have been replaced. The change of is now confirmed. In the table, the arrow ( <== ) is no longer
displayed next to the entry for this nozzle holder.
5

5 Single Functions User Manual SIPLACE F5/F5 HM
5.2 Single functions, Gantry Software version SR.407.xx 01/2001 US Edition
204
5.2.8 "Nozzle changer configuration revolver head" screen for 12-nozzle C&P
head
5
Å In the current screen for the single function for Gantry, click the symbol .
NOTE
The nozzle changer must be installed and configured in the machine options. When calling
this screen the nozzles on the placement head are returned to the nozzle changer. 5
The user interface is switched to the "Nozzle changer configuration revolver head" screen (see
Fig. 5.2 - 12
). 5
5
Fig. 5.2 - 12 "Nozzle changer configuration revolver head" screen (12-nozzle Collect&Place head)