10 Component handling User Manual SIPLACE F5/F5 HM 10.2 Technical dat a for the feeder mo dules Sof tware version SR. 407.xx 01/2001 US E dition 440 10. 2.2 3 x 8 mm S mod ule 10 Fig. 10.2 - 2 3 x 8 mm S module Item no. …

User Manual SIPLACE F5/F5 HM 10 Component handling
Software version SR.407.xx 01/2001 US Edition 10.2 Technical data for the feeder modules
439
10.2 Technical data for the feeder modules
The following pages contain diagrams of all the feeder modules, technical data and the module
setting options on the placement system. 10
10.2.1 8 mm S II module
10
Fig. 10.2 - 1 8 mm S II module
Item no. 00141096-xx
Width 30 mm
Tracks per module 2
Maximum number of modules 2 x 20
Magazine capacity for 7" reels Approx. 10000
Reel diameter 7" - 15" (up to 381 mm)
Feeding stroke (variable) 2mm / 4mm
Cycle time 60 ms
Main power supply 30 VDC

10 Component handling User Manual SIPLACE F5/F5 HM
10.2 Technical data for the feeder modules Software version SR.407.xx 01/2001 US Edition
440
10.2.2 3 x 8 mm S module
10
Fig. 10.2 - 2 3 x 8 mm S module
Item no. 00141098-xx
Width 30 mm
Tracks per module 3
Maximum number of modules 2 x 20
Magazine capacity for 7" reels Approx. 10,000
Reel diameter 7" - 15" (up to 381 mm)
Feeding stroke (variable) 2mm / 4mm
Cycle time 60 ms
Main power supply 30 VDC
LIMITED COMPONENT PICK-UP OPTIONS:
If the following combination of track, location and conveyor track is used, components cannot be
picked up from triple conveyors.
Location/Track Conveyor track
1/115 3
3/1 1 10

User Manual SIPLACE F5/F5 HM 10 Component handling
Software version SR.407.xx 01/2001 US Edition 10.2 Technical data for the feeder modules
441
10.2.3 3 x 8 mm S module for 0201/0402 components
Fig. 10.2 - 3 3x8mm S module for 0201/0402 components
Article number 00141099-xx
Width 30 mm
Component range 0201, 0402
Tracks per module 3
Maximum number of modules (DCA) 2 x 20
Stock of components for 7” reels approx. 10,000 – 15,000
Data specific to reel diameter 7” – 15”, maximum 381 mm
Transport distance (adjustable) 2mm ( 4mm)
Cycle time 60 ms
Power supply 30 V DC
LIMITED COMPONENT PICK-UP OPTIONS:
If the following combination of track, location and conveyor track is used, components cannot be
picked up from triple conveyors.
Location/Track Conveyor track
1/115 3
3/1 1 10