B-116 Procedur e of initial setti ng (Continue d) Step No. Do This 7 Make sure that the r eading is "normal open" for a positive pressure sensor or "norm al close" for a negative pressure sensor. - Wh…

100%1 / 720
B-115
Procedure of initial setting (Continued)
Step No. Do This
4
The display of the sensor has changed to the "OUT1 output
pattern setting" mode.
[Positive pressure] [Negative pressure]
5
Make sure that the reading is "normal open" for a positive
pressure sensor or "normal close" for a negative pressure sensor.
- When the reading is not proper,
Press the or button to change the reading.
[Positive pressure] [Negative pressure]
Normal open Normal close
6
Press the SET button to finalize the setting.
- The display has changed to the "OUT2 output pattern setting"
mode.
[Positive pressure] [Negative pressure]
B-116
Procedure of initial setting (Continued)
Step No. Do This
7
Make sure that the reading is "normal open" for a positive
pressure sensor or "normal close" for a negative pressure sensor.
- When the reading is not proper,
Press the or button to change the reading.
[Positive pressure] [Negative pressure]
Normal open Normal close
8
Press the SET button to finalize the setting.
- The display has changed to the "response time setting" mode.
9
Press the or button to set the reading at 2.5 ms.
10
Press the SET button to finalize the setting.
- The display has changed to the "automation/manual setting"
mode.
11
Press the or button to set the manual mode.
12
Press the SET button to finalize the setting.
- The display has returned to the "measurement" mode.
Continued in the next section.
B-117
4-1-2. Pressure setting
Procedure of pressure setting [positive pressure]
Step No. Do This
(Continued from the previous section)
1
Press the SET button.
- The display has changed to the "pressure setting mode - setting
value 1".
Displays alternately
2
Set the setting value 1.
- To change the reading, press the or button.
3
Press the SET button to finalize the setting.
- The display has changed to the "pressure setting mode - setting
value 2".
Displays alternately
4
Set the setting value 2.
- Set the same value as the setting value 1 by pressing the or
button.
5
Press the SET button to finalize the setting.
- The display has changed to the "pressure setting mode - setting
value 3".
Displays alternately