DFD6361-Maintenance.pdf - 第342页
D-57 B0583 : Z 1-axis s etup error ( error detecti on.) Error c ode B0583 Message Z1- axis setup er ror (erro r detec tion.) W hat wa s detected The Z 1-axis se tup oper ation ended within the Z- axis high-speed mov emen…

D-56
B0582 : Z1-axis calibrate sensor.
Error code
B0582
Optional accessory
Message
Z1-axis calibrate sensor.
What was
detected
Sensor calibration setup was not completed before Z1-axis non-contact
setup process initiation.
During what
operation it
occurred
At the beginning of Z1-axis non-contact setup.
State after
detection
The Z1-axis non-contact setup process is discontinued.
Phenomenon Probable causes Remedy Reference
What to do
Recovery
(1) Cancel the alarm.
(2) Execute sensor calibration setup.
Maintenance level Maintenance personnel level Hazard level
Measuring equipment used Tools Replacement parts Protective gear

D-57
B0583 : Z1-axis setup error (error detection.)
Error code
B0583
Message
Z1-axis setup error (error detection.)
What was
detected
The Z1-axis setup operation ended within the Z-axis high-speed movement
range.
During what
operation it
occurred
During Z1-axis setup operation.
State after
detection
The setup operation ends after the Z1-axis returns to its origin.
Setup data value registration does not take place.
Phenomenon Probable causes Remedy Reference
What to do
The error occurs
frequently.
Erroneous detection
occurs during setup
operation due to
water drops on the
setup position
section.
Increase the setup
data value for the
setup blow time
setting.
With an air-
injection gun,
remove water drops
from the table
upper surface and
spindle section.
Recovery
(1) Cancel the alarm.
(2) Select the setup operation again.
Maintenance level Maintenance personnel level Hazard level
Measuring equipment used Tools Replacement parts Protective gear

D-58
B0584 : Z1-axis setup error (Z-axis position error.)
Error code
B0584
Message
Z1-axis setup error (Z-axis position error.)
What was
detected
The Z1-axis did not operate in Z1-axis setup process.
During what
operation it
occurred
During Z1-axis setup operation.
State after
detection
The Z1-axis returns to its origin and the setup operation terminates.
Setup data value registration does not take place.
Phenomenon Probable causes Remedy Reference
What to do
The error recurs
even when setup is
attempted again.
The setup wiring
between
the SETUP board
and Z-axis driver is
broken.
Contact your
nearest DISCO
Service Office.
Recovery
(1) Cancel the alarm.
(2) Select the setup operation again.
Maintenance level Maintenance personnel level Hazard level
Measuring equipment used Tools Replacement parts Protective gear