DFD6361-Maintenance.pdf - 第394页
D-109 A0534 : N ot found in dex check targ et. Error c ode A0534 Message Not found in dex check tar get. W hat wa s detected Error displ ay is done if t he pattern is not found during index check out after alignm ent. Du…

D-108
A0533 :Alignment time limit over.
Error code
A0533
Message
Alignment time limit over.
What was
detected
The error was displayed when the alignment time was exceeded the value
specified in the column <TIME OUT> on the ALIGNMENT DATA screen
[screen 3.1.3].
During what
operation it
occurred
During auto alignment operation.
State after
detection
Auto alignment operation is discontinued.
Phenomenon Probable causes Remedy Reference
What to do
The error occurs
frequently.
Thedevicedata
setting for doing the
operation is
incorrect.
Change the device
data.
The workpiece
attachment to the
frame is displaced
more than 5° in the θ
direction.
Reattach the
workpiece with the
attachment
precision of 5° or
less.
The value specified
in the column
<TIME OUT> on the
ALIGNMENT
DATA screen [screen
3.1.3] is too short.
Correct the value
specified in the
column <TIME
OUT> on the
ALIGNMENT
DATA screen
[screen 3.1.3].
Recovery
(1) Cancel the alarm, then the ERROR RECOVERY (ALIGNMENT)
screen is displayed.
(2) Perform the error recovery steps indicated on the screen.
Maintenance level Maintenance personnel level Hazard level
Measuring equipment used Tools Replacement parts Protective gear

D-109
A0534 : Not found index check target.
Error code
A0534
Message
Not found index check target.
What was
detected
Error display is done if the pattern is not found during index checkout after
alignment.
During what
operation it
occurred
During auto alignment operation.
State after
detection
Auto alignment operation is temporarily halted.
Phenomenon Probable causes Remedy Reference
What to do
The error occurs
frequently.
The workpiece is
partially soiled.
Perform the manual
alignment and then
continue machining
the workpiece.
Recovery
(1) Cancel the alarm, then the ERROR RECOVERY (ALIGNMENT)
screen is displayed.
(2) Perform the error recovery steps indicated on the screen.
Maintenance level Maintenance personnel level Hazard level
Measuring equipment used Tools Replacement parts Protective gear

D-110
A0535 : Index check Y position error. (Y)
Error code
A0535
Message
Index check Y position error. (Y)
What was
detected
In searching a pattern during Y-direction movement in index checkout, the
Y-coordinate exceeded the preset value in the column <INDEX CHECK:
PERMISSION> on the ALIGNMENT DATA screen [screen 3.1.3]
During what
operation it
occurred
During Y-direction movement in index checkout of auto alignment
operation.
State after
detection
Auto alignment operation is temporarily halted.
Phenomenon Probable causes Remedy Reference
What to do
The error occurs
frequently.
The value specified
in the column
<INDEX CHECK:
PERMISSION> on
the ALIGNMENT
DATA screen [screen
3.1.3] is too small.
Correct the value
specified in the
column <INDEX
CHECK:
PERMISSION> on
the ALIGNMENT
DATA screen
[screen 3.1.3].
Recovery
(1) Cancel the alarm, then the ERROR RECOVERY (ALIGNMENT)
screen is displayed.
(2) Perform the error recovery steps indicated on the screen.
Maintenance level Maintenance personnel level Hazard level
Measuring equipment used Tools Replacement parts Protective gear