DFD6361-Maintenance.pdf - 第373页

D-88 V1015 : D own er ror (Low er arm U pper cyli nder). Error c ode V1015 Message Down error (Low er arm Upper cyl inder). W hat wa s detected There is no inp ut from D own-end sensor, whe n the lower arm upper cylinder…

100%1 / 720
D-87
V1014 : Up error (Lower arm Upper cylinder).
Error code
V1014
Message
Up error (Lower arm Upper cylinder).
What was
detected
There is no input from Up-end sensor, when the lower arm upper cylinder
moves upward.
During what
operation it
occurred
Lower arm up operation.
State after
detection
Transport stops.
Phenomenon Probable causes Remedy Reference
What to do
The error occurs
even though the
lower arm upper
cylinder ascends
normally.
The sensor position
is deviated.
Adjust the position
so that there is
sensor input when
the lower arm
upper cylinder is in
the up state.
The sensor is
defective.
Replace the sensor.
The lower arm
upper cylinder does
not ascend.
The upper cylinder
piping of the lower
arm section is bent of
clogged.
Contact your
nearest DISCO
Service Office.
Recovery
(1) Cancel the alarm, and then the ERROR RECOVERY (HANDLING)
screen is displayed.
(2) Perform the error recovery steps indicated on the screen.
Maintenance level Maintenance personnel level Hazard level
Measuring equipment used Tools Replacement parts Protective gear
D-88
V1015 : Down error (Lower arm Upper cylinder).
Error code
V1015
Message
Down error (Lower arm Upper cylinder).
What was
detected
There is no input from Down-end sensor, when the lower arm upper
cylinder moves downward.
During what
operation it
occurred
Lower arm down operation.
State after
detection
Transport stops.
Phenomenon Probable causes Remedy Reference
What to do
The error occurs
even when the
lower arm upper
cylinder descends
normally.
The sensor position
is deviated.
Adjust the position
so that there is
sensor input when
the lower upper
cylinder arm is in
the down state.
The sensor is
defective.
Replace the sensor.
The lower arm
upper cylinder does
not descend.
The upper cylinder
piping of the lower
arm section is bent or
clogged.
Contact your
nearest DISCO
Service Office.
Recovery
(1) Cancel the alarm, and then the ERROR RECOVERY (HANDLING)
screen is displayed.
(2) Perform the error recovery steps indicated on the screen.
Maintenance level Maintenance personnel level Hazard level
Measuring equipment used Tools Replacement parts Protective gear
D-89
V1016 : Up error (Lower arm Lower cylinder).
Error code
V1016
Message
Up error (Lower arm Lower cylinder).
What was
detected
There is no input from Up-end sensor, when the lower arm lower cylinder
moves upward.
During what
operation it
occurred
Lower arm up operation.
State after
detection
Transport stops.
Phenomenon Probable causes Remedy Reference
What to do
The error occurs
even when the
lower arm lower
cylinder ascends
normally.
The sensor position
is deviated.
Adjust the position
so that there is
sensor input when
the lower arm
lower cylinder is in
the up state.
The sensor is
defective.
Replace the sensor.
The lower arm
lower cylinder does
not ascend.
The lower cylinder
piping of the lower
arm section is bent of
clogged.
Contact your
nearest DISCO
Service Office.
Recovery
(1) Cancel the alarm, and then the ERROR RECOVERY (HANDLING)
screen is displayed.
(2) Perform the error recovery steps indicated on the screen.