instruction-manual-product-monitoring-data-acquisition-monitouch-V9-hardware-en.pdf - 第42页

2 1. Advanced Model 2-11 Specifications V907xiW with DUR- 00 External Dimensions and Panel Cut-out Dimensions 133.4 +0.5 -0 187.2 +0.5 -0 60.3 201.6 147.6 186.2 132.4 53.1 7.2 85.3 53.1 6.0 84.1 85.3 59.1 84.1 V9071iW V9…

100%1 / 122
2-10 1. Advanced Model
V9070iW External Dimensions and Panel Cut-out Dimensions
133.4
+0.5
-0
187.2
+0.5
-0
59.1
201.6
147.6
186.2
132.4
53.1
6.0
Side view
Panel cut-out dimensions
Rear view
Bottom view
(Unit: mm)
Front view
2
1. Advanced Model 2-11
Specifications
V907xiW with DUR-00 External Dimensions and Panel Cut-out
Dimensions
133.4
+0.5
-0
187.2
+0.5
-0
60.3
201.6
147.6
186.2
132.4
53.1
7.2
85.3
53.1
6.0
84.1
85.3
59.1
84.1
V9071iW V9070iW
V9071iW
V9070iW
Side view
Panel cut-out dimensions
Rear view
Bottom view
(Unit: mm)
Front view
2-12 2. Standard Model
2. Standard Model
General Specifications
Item V9150iX V9150iXD V9120iS V9120iSD
Standards KC
KC
*1
CE (EN61000-6-2,
EN61000-6-4,
EN50581)
*1
UL508
(File No. E313548)
Radio laws
(Japan: TELEC)
*3
KC
KC
*1
CE (EN61000-6-2,
EN61000-6-4,
EN50581)
*1
UL508
(File No. E313548)
ANSI/ISA 12.12.01
(File No.
E315977)
*2
Radio laws
(Japan: TELEC)
*3
Power Supply
Permissible Voltage
Range
100 to 240 VAC
-15 % to +10 %
(47 to 63 Hz)
24 VDC 10 %
100 to 240 VAC
-15 % to +10 %
(47 to 63 Hz)
24 VDC 10 %
Permissible
Momentary Power
Failure
Within 20 ms
(100 VAC or higher)
Within 1 ms
Within 20 ms
(100 VAC or higher)
Within 1 ms
Power Consumption
(Max. Rating)
90 VA or less 40 W or less 70 VA or less 28 W or less
Rush Current
30 A or less, 3 ms
(surrounding air
temperature at 25 °C)
19 A or less, 7 ms
(surrounding air
temperature at 25 °C)
30 A or less, 3 ms
(surrounding air
temperature at 25 °C)
18 A or less, 5 ms
(surrounding air
temperature at 25 °C)
Withstand Voltage
AC external terminals to FG: 1,500 VAC for 1 minute,
DC external terminals to FG: 500 VAC for 1 minute
Insulation Resistance
AC external terminals to FG: 500 VDC at 10 M or more,
DC external terminals to FG: 500 VDC at 10 M or more
Physical Environment
Surrounding Air
Temperature
0 °C to +40 °C
*4
0 °C to +50 °C
*4
Storage
Surrounding Air
Temperature
-10 °C to +50 °C
*4
-10 °C to +60 °C
*4
Operational
Ambient Humidity
85 % RH or less (without dew condensation)
*4
Storage Ambient
Humidity
85 % RH or less (without dew condensation)
*4
Altitude 2000 m or less
Atmosphere No corrosive gas, no excessive dust, and no conductive dust
Overvoltage
Category
*5
Category II
Contamination
Level
*6
Contamination level 2
Mechanical
Working
Conditions
Vibration
Resistance
JIS B 3502 (IEC61131-2) compliant
Vibration frequency: 5 to 9 Hz Half-amplitude: 3.5 mm, Vibration frequency: 9 to 150 Hz Constant
acceleration: 9.8 m/s
2
(1 G), X, Y, and Z: 3 directions (10 times each)
Shock Resistance
JIS B 3502 (IEC61131-2) compliant
Peak acceleration: 147 m/s
2
(15 G),
X, Y, and Z: 3 directions, 3 times each (18 times in total)
Electrical
Working
Conditions
Noise Resistance
Noise voltage:
1500 Vp-p,
Pulse width: 1 s,
Rising time: 1 ns
(Measured using a
noise simulator)
Noise voltage:
1000 Vp-p,
Pulse width: 1 s,
Rising time: 1 ns
(Measured using a
noise simulator)
Noise voltage: 1500 Vp-p, Pulse width: 1 s,
Rising time: 1 ns
(Measured using a noise simulator)
Static Electricity
Discharge
Resistance
Compliant with IEC61000-4-2, contact: 6 kV, air: 8 kV