instruction-manual-product-monitoring-data-acquisition-monitouch-V9-hardware-en.pdf - 第43页
2-12 2. Standard Model 2. Standard Model General Specifications Item V9150iX V9150iX D V9120iS V9120iSD Standards KC KC *1 CE (EN61000-6-2, EN61000-6-4, EN50581) *1 UL508 (File No. E313548) Radio laws (Japan: TEL…

2-12 2. Standard Model
2. Standard Model
General Specifications
Item V9150iX V9150iXD V9120iS V9120iSD
Standards KC
KC
*1
CE (EN61000-6-2,
EN61000-6-4,
EN50581)
*1
UL508
(File No. E313548)
Radio laws
(Japan: TELEC)
*3
KC
KC
*1
CE (EN61000-6-2,
EN61000-6-4,
EN50581)
*1
UL508
(File No. E313548)
ANSI/ISA 12.12.01
(File No.
E315977)
*2
Radio laws
(Japan: TELEC)
*3
Power Supply
Permissible Voltage
Range
100 to 240 VAC
-15 % to +10 %
(47 to 63 Hz)
24 VDC 10 %
100 to 240 VAC
-15 % to +10 %
(47 to 63 Hz)
24 VDC 10 %
Permissible
Momentary Power
Failure
Within 20 ms
(100 VAC or higher)
Within 1 ms
Within 20 ms
(100 VAC or higher)
Within 1 ms
Power Consumption
(Max. Rating)
90 VA or less 40 W or less 70 VA or less 28 W or less
Rush Current
30 A or less, 3 ms
(surrounding air
temperature at 25 °C)
19 A or less, 7 ms
(surrounding air
temperature at 25 °C)
30 A or less, 3 ms
(surrounding air
temperature at 25 °C)
18 A or less, 5 ms
(surrounding air
temperature at 25 °C)
Withstand Voltage
AC external terminals to FG: 1,500 VAC for 1 minute,
DC external terminals to FG: 500 VAC for 1 minute
Insulation Resistance
AC external terminals to FG: 500 VDC at 10 M or more,
DC external terminals to FG: 500 VDC at 10 M or more
Physical Environment
Surrounding Air
Temperature
0 °C to +40 °C
*4
0 °C to +50 °C
*4
Storage
Surrounding Air
Temperature
-10 °C to +50 °C
*4
-10 °C to +60 °C
*4
Operational
Ambient Humidity
85 % RH or less (without dew condensation)
*4
Storage Ambient
Humidity
85 % RH or less (without dew condensation)
*4
Altitude 2000 m or less
Atmosphere No corrosive gas, no excessive dust, and no conductive dust
Overvoltage
Category
*5
Category II
Contamination
Level
*6
Contamination level 2
Mechanical
Working
Conditions
Vibration
Resistance
JIS B 3502 (IEC61131-2) compliant
Vibration frequency: 5 to 9 Hz Half-amplitude: 3.5 mm, Vibration frequency: 9 to 150 Hz Constant
acceleration: 9.8 m/s
2
(1 G), X, Y, and Z: 3 directions (10 times each)
Shock Resistance
JIS B 3502 (IEC61131-2) compliant
Peak acceleration: 147 m/s
2
(15 G),
X, Y, and Z: 3 directions, 3 times each (18 times in total)
Electrical
Working
Conditions
Noise Resistance
Noise voltage:
1500 Vp-p,
Pulse width: 1 s,
Rising time: 1 ns
(Measured using a
noise simulator)
Noise voltage:
1000 Vp-p,
Pulse width: 1 s,
Rising time: 1 ns
(Measured using a
noise simulator)
Noise voltage: 1500 Vp-p, Pulse width: 1 s,
Rising time: 1 ns
(Measured using a noise simulator)
Static Electricity
Discharge
Resistance
Compliant with IEC61000-4-2, contact: 6 kV, air: 8 kV

2
2. Standard Model 2-13
Specifications
Mounting
Conditions
Weight Approx. 4.7 kg Approx. 2.5 kg
Dimensions
W H D
382.8 312.8 80.8 mm 327.8 261.0 54.9 mm
Panel Cut-out
Dimensions
369.4 299.4 mm 313.0 246.2 mm
Case Color Front: Silver; Rear: Light gray Light gray
Material Front: Aluminum; Rear: PC resin PC resin
Item V9150iX V9150iXD V9120iS V9120iSD
+0.5
0
+0.5
0
+0.5
0
+0.5
0
Item V9100iS V9100iSD V9080iSD
Standards KC
KC
*1
CE (EN61000-6-2, EN61000-6-4)
*1
UL508 (File No. E313548)
ANSI/ISA 12.12.01 (File No. E315977)
*2
Radio laws (Japan: TELEC)
*3
Power Supply
Permissible Voltage
Range
100 to 240 VAC
-15 % to +10 %
(47 to 63 Hz)
24 VDC 10 %
Permissible
Momentary Power
Failure
Within 20 ms
(100 VAC or higher)
Within 1 ms
Power Consumption
(Max. Rating)
70 VA or less 28 W or less
Rush Current
30 A or less, 3 ms
(ambient temperature at
25 °C)
17 A or less, 6 ms (ambient temperature at 25 °C)
Withstand Voltage
AC external terminals to FG: 1,500 VAC for 1 minute,
DC external terminals to FG: 500 VAC for 1 minute
Insulation Resistance
AC external terminals to FG: 500 VDC at 10 M or more,
DC external terminals to FG: 500 VDC at 10 M or more
Physical Environment
Operational
Ambient
Temperature
0 °C to +50 °C
*4
Storage Ambient
Temperature
-10 °C to +60 °C
*4
Operational
Ambient Humidity
85 % RH or less (without dew condensation)
*4
Storage Ambient
Humidity
85 % RH or less (without dew condensation)
*4
Altitude 2000 m or less
Atmosphere No corrosive gas, no excessive dust, and no conductive dust
Overvoltage
Category
*5
Category II
Contamination
Level
*6
Contamination level 2
Mechanical
Working
Conditions
Vibration
Resistance
JIS B 3502 (IEC61131-2) compliant
Vibration frequency: 5 to 9 Hz Half-amplitude: 3.5 mm, Vibration frequency: 9 to 150 Hz Constant
acceleration: 9.8 m/s
2
(1 G), X, Y, and Z: 3 directions (10 times each)
Shock Resistance
JIS B 3502 (IEC61131-2) compliant
Peak acceleration: 147 m/s
2
(15 G),
X, Y, and Z: 3 directions, 3 times each (18 times in total)
Electrical
Working
Conditions
Noise Resistance
Noise voltage: 1500 Vp-p, Pulse width: 1 s, Rising time: 1 ns
(Measured using a noise simulator)
Static Electricity
Discharge
Resistance
Compliant with IEC61000-4-2, contact: 6 kV, air: 8 kV
Mounting
Conditions
Weight Approx. 2.0 kg Approx. 1.3 kg
Dimensions
W H D
303.8 231.0 54.0 mm 235.0 180.0 48.9 mm
Panel Cut-out
Dimensions
289.0 216.2 mm 220.5 165.5 mm
+0.5
0
+0.5
0
+0.5
0
+0.5
0