instruction-manual-product-monitoring-data-acquisition-monitouch-V9-hardware-en.pdf - 第78页
3 2. Specifications of Components 3-13 Names and Specifications of Components Recommended Connec tor The following connector is recommended for custom-made cables. Applications Modular Jack (MJ1/MJ2) The modular jacks ar…

3-12 2. Specifications of Components
2. Specifications of Components
Serial Connector (CN1)
This connector is used to connect a controller or barcode reader via RS-232C, or connect a controller
via RS-422/485.
For the V907xiW/V9060iTD, attach the optional “DUR-00” unit to add this serial connector.
The serial connector pins correspond to the signals as shown below.
*1 The signal level can be changed between RS-232C and RS-422/485 in the configuration software.
When RS-232C is selected, set DIP switches 5 and 7 to the OFF position.
(For details on DIP switches, refer to “DIP Switches (DIPSW)” (page 3-30).)
*2 When RS-422/485 is selected, +5 V is output from pin No. 9.
This +5 V is used as the power supply for the external terminating resistance when performing RS-422/485
communication. It cannot be used as an external power supply.
Bottom view Bottom view
V9100 V9080
Rear view
V907xiW
CN1 (D-sub 9-pin, female)
Pin No.
RS-232C
*1
RS-422 / RS-485
*1
Signal Description Signal Description
1 NC Not used + RD Receive data (+)
2 RD Receive data RD Receive data ()
3 SD Send data SD Send data ()
4 NC Not used + SD Send data (+)
5 SG Signal ground SG Signal ground
6 NC Not used + RTS Request to send (+)
7 RTS Request to send RTS Request to send ()
8 CTS Clear to send NC Not used
9 NC Not used + 5 V
Use prohibited
*2
9
5
6
1

3
2. Specifications of Components 3-13
Names and Specifications of Components
Recommended Connector
The following connector is recommended for custom-made cables.
Applications
Modular Jack (MJ1/MJ2)
The modular jacks are used for connection to a screen program transfer cable (MJ1 only), temperature
controller, barcode reader, and other devices.
The pins of MJ1 and MJ2 correspond to the signals as shown below.
V9150, V9120, V9100, V910xiW, V9080 series
*1 When the mounting angle is 15 to 60, or 120 to 135, the +5 V external power supply at MJ1/MJ2 of the V9
series unit is impossible.
*2 Allowable current for the +5 V external power supply at MJ1/MJ2 of the V9 series unit
For MJ1 and MJ2, the maximum allowable current is 150 mA in total (only when the mounting angle is 60 to
120).
Recommended
Connector
17JE-23090-02(D8C)-CG
manufactured by DDK
D-sub 9-pin / male / inch screw thread (#4-40UNC) type
/ with hood / lead and cadmium free
Application V-SFT-6 Setting Refer to
PLC/temperature controller connection Required
V9 Series Connection ManualBarcode reader connection Required
Multi-link/Multi-link2 communication Required
Bottom view Bottom view
V9100 V907xiW
MJ1/2 Pin No. Signal Description
1 +SD/RD RS-485 + data
2 SD/RD RS-485 data
3+5 V
Externally supplied +5 V
*1
*2
4+5 V
5SG
Signal ground
6SG
7 RD RS-232C receive data
8 SD RS-232C send data
8 76 5 43 21

3-14 2. Specifications of Components
V907xiW, V9060iTD series
*1 The MJ2 sliding switch is on the rear side of the V907xiW, V9060iTD.
*2 When the mounting angle is 15 to 60, or 120 to 135, the +5 V external power supply at MJ1/MJ2 of the V9
series unit is impossible.
*3 Allowable current for the +5 V external power supply at MJ1/MJ2 of the V9 series unit
For MJ1 and MJ2, the maximum allowable current is 150 mA in total (only when the mounting angle is 60 to
120).
Applications
*1 The ladder transfer function cannot be used simultaneously with 1:n communication (multi-drop) or multi-link
communication.
MJ1/2
Pin No.
MJ1 MJ2
Signal Description
Sliding
Switch
*1
Signal Description
1 +SD/RD RS-485 + data
Up +SD/RD RS-485 + data
Down +SD RS-422 + send data
2 -SD/RD RS-485 - data
Up -SD/RD RS-485 - data
Down -SD RS-422 - send data
3+5V
Externally supplied
+5 V
*2
*3
-
+5V
Externally supplied
+5 V
*2
*3
4+5V +5V
5SG
Signal ground
SG
Signal ground
6SG SG
7 RD RS-232C receive data
Up RD RS-232C receive data
Down +RD RS-422 + receive data
8 SD RS-232C send data
Up SD RS-232C send data
Down -RD RS-422 - receive data
8 76 5 43 21
Rear view
Sliding switch (Upon delivery: Up)
Up: RS-232C, RS-485 (2-wire connection)
Down: RS-422 (4-wire connection)
Example: V907xiW
Application V-SFT-6 Setting Refer to
PLC/temperature controller connection Required
V9 Series Connection ManualBarcode reader connection Required
Multi-link/Multi-link2 communication Required
Ladder transfer function
*1
Required V9 Series Reference Manual 2
Screen program transfer Not required V9 Series Operation Manual
Printer connection Required V9 Series Reference Manual 1