00198711-01_UM_X-Serie-S_EN.pdf - 第122页
3 Technical data and assemblies Instruction manual SIPLACE X-Series 3.5 Placement head From software version 713.0 Edition 11/2019 122 3.5.3 Sensor for the component reject bin The sensor for the component reject bin mon…

Instruction manual SIPLACE X-Series 3 Technical data and assemblies
From software version 713.0 Edition 11/2019 3.5 Placement head
121
3.5.2.2 Technical data for SIPLACE SpeedStar (C&P20 P2)
SIPLACE SpeedStar (C&P20 P2)
With component camera type 48
Component range
*a
*)a Please note that the placeable component range is also affected by the pad geometry, the customer-spe-
cific standards, the component packaging tolerances and the component tolerances.
0.12 mm x 0.12 (0201 metric) to 2220, Melf, SOT, SOD, Bare-Die,
Flip-Chip
Component spec.
Max. height
Min. lead pitch
Min. lead width
Min. ball pitch
Min. ball diameter
Min. dimensions
Max. dimensions
Max. weight
4 mm
70 µm
30 µm
100 µm
50 µm
0.12 mm x 0.12 mm
8.2 mm x 8.2 mm
1 g
Set-down force Touchless Placement, 1.3 N ± 0.5 N (standard)
0.5 N - 4.5 N
Nozzle types 40xx/60xx
X/Y accuracy
*b
*)b The accuracy values fulfill the conditions in the SIPLACE scope of supply and services.
± 35 µm/3σ
Angular accuracy ± 0.5° / 3σ
Illumination level 5

3 Technical data and assemblies Instruction manual SIPLACE X-Series
3.5 Placement head From software version 713.0 Edition 11/2019
122
3.5.3 Sensor for the component reject bin
The sensor for the component reject bin monitors whether the reject bin is seated correctly in its
mount.
– If the reject bin was not inserted correctly, the placement machine cannot be started.
– If the reject bin jumps out of its mount during the placement process, the placement machine
will be stopped immediately to avoid a head crash.
3.5.4 Vacuum pump (optional)
The vacuum pumps for the SIPLACE SpeedStar are fitted behind the COT inserts at locations 1
and 4, in the machine base. There are two types available:
– Vacuum pump VX4.25
– Vacuum pump VX4.25/0-47 IE3
3.5.4.1 Overview - type VX4.25
Item no. 03128463-xx Vacuum pump VX4.25
3
Fig. 3.5 - 3 Overview - vacuum pump
(1) Installation location for vacuum pump
(2) Vacuum pump VX 4.25
(1)
(2)

Instruction manual SIPLACE X-Series 3 Technical data and assemblies
From software version 713.0 Edition 11/2019 3.5 Placement head
123
3.5.4.2 Overview - type VX4.25/0-47 IE3
Item no. 03224400-xx Vacuum pump VX4.25/0-47 IE3
3
Fig. 3.5 - 4 Overview - vacuum pump
(1) Installation location for vacuum pump
(2) Vacuum pump VX 4.25 IE3
3.5.4.3 Safety instructions for vacuum pumps
3
3.5.4.4 Description
Only the SIPLACE SpeedStar can be operated with the vacuum pump. The SIPLACE SpeedStar
with vacuum pump is available as an option for the SIPLACE X-Series S.
When operated together with a vacuum pump, the compressed air consumption for the SpeedStar
(C&P20P/P2) head can be reduced considerably. A vacuum pump can supply up to two Speed-
Star (C&P20P/P2) heads. A maximum of two vacuum pumps can therefore be used (for 4x
C&P20P/P2). The running costs will fall according to the energy costs incurred.
(1)
(2)
WARNING
Please observe the safety instructions in the instruction manual supplied for the vac-
uum pump.