00198711-01_UM_X-Serie-S_EN.pdf - 第254页

5 Tasks at the placement machine Ins truction manual SIPLACE X-Series S 5.7 Indicator lamps with horn From software version 713.0 Edition 11/2019 254 5.7.1.2 Three color indicator lamp (optional) Fig. 5.7 - 2 Indicator l…

100%1 / 360
Instruction manual SIPLACE X-Series S 5 Tasks at the placement machine
From software version 713.0 Edition 11/2019 5.7 Indicator lamps with horn
253
5.7 Indicator lamps with horn
5.7.1 Overview
These indicator lamps are used to signal operating statuses and malfunctions of the placement
machine. The horn indicates when an alert has occurred. SIPLACE placement machines can ei-
ther be fitted with a two or three color indicator lamp. The relevant indicator lamp system (two or
three color) is set in the autoconfiguration, see installation guide for station software, Item No.
00196771-xx.
5.7.1.1 Two color indicator lamp (standard)
Fig. 5.7 - 1 Indicator lamps for operating states (example of SIPLACE X2 S / X3 S / X4 S shown)
L1 White indicator lamp, right
L2 Green indicator lamp, right
L3 White indicator lamp, left
L4 Green indicator lamp, left
T Direction of PCB transport
(L2)
(L1)
(L3)
(L4)
5 Tasks at the placement machine Instruction manual SIPLACE X-Series S
5.7 Indicator lamps with horn From software version 713.0 Edition 11/2019
254
5.7.1.2 Three color indicator lamp (optional)
Fig. 5.7 - 2 Indicator lamps for operating states (example of SIPLACE X2 S / X3 S / X4 S shown)
L1 red indicator lamp
L2 yellow indicator lamp
L3 green indicator lamp
(L2)
(L1)
(L3)
Instruction manual SIPLACE X-Series S 5 Tasks at the placement machine
From software version 713.0 Edition 11/2019 5.7 Indicator lamps with horn
255
5.7.2 Status displays and their meanings
5.7.2.1 Configuration of three-color indicator lamp and audio signal
Fig. 5.7 - 3 Configuration of three-color indicator lamp and audio signal