00198711-01_UM_X-Serie-S_EN.pdf - 第309页

Instruction manual SIPLACE X-Series S 6 Station extensions From software version 713.0 Edition 11/2019 6.2 PCB barcode scanner 309 6.2 PCB barcode scanner 6.2.1 Description The PCB barcode reader is used to au tomaticall…

100%1 / 360
6 Station extensions Instruction manual SIPLACE X-Series S
6.1 Nozzle changer From software version 713.0 Edition 11/2019
308
6.1.4.6 Component reject bin for the SIPLACE TwinStar
A component reject bin can be installed for the SIPLACE TwinStar. This is positioned next to the
stationary camera.
6
Fig. 6.1 - 17 Component reject bin for the SIPLACE TwinStar
Instruction manual SIPLACE X-Series S 6 Station extensions
From software version 713.0 Edition 11/2019 6.2 PCB barcode scanner
309
6.2 PCB barcode scanner
6.2.1 Description
The PCB barcode reader is used to automatically record and decode barcodes on PCBs. The
PCB barcode scanners are installed on a special frame on the input side of the placement ma-
chine on the PCB
conveyor. Depending
on the position of the barcode strips, the barcode scanner can be attached in a few simple
steps so that the strips can be read parallel to or across the PCB transport direction.
When using dual conveyors, four board barcode readers can be retrofitted. These can scan both
the top or bottom of the boards on both conveyor lanes.
There are two variants of the barcode scanner:
2D board code reader
This code reader processes barcodes and matrix codes. Matrix code is primarily used when
there is
not enough space for barcode labels. 6
6.2.2 Technical data - 2D code reader
6
Dimensions (L x W x H) 55 mm x 42 mm x 22 mm
Weight 125 grams
Code types 2D Data Matrix ECC 0, 50, 80, 100, 140 and 200
Data Matrix ECC200
QR Code, MicroQR Code
Barcode length
Single conveyor
Dual conveyor, asynchronous
Dual conveyor, synchronous
Max. 40 characters
Max. 40 characters
Max. 40 characters
Data interface RS232, USB 2.0
Electrical connection 15-pin D-Sub HD plug
Operating voltage 5 V- to 24 V-
6 Station extensions Instruction manual SIPLACE X-Series S
6.3 Input conveyor and output conveyor extensions From software version 713.0 Edition 11/2019
310
6.3 Input conveyor and output conveyor extensions
Item no. 00519971.xx Input conveyor extension for single conveyor
Item no. 00519972.xx Input conveyor extension for dual conveyor
Item no. 00519973.xx Output conveyor extension for single conveyor
Item no. 00519974.xx Output conveyor extension for dual conveyor
6.3.1 Description
The input/output conveyor extensions can be fitted as board buffers between two machines. This
involves fitting an output conveyor extension to the output conveyor of the first placement machine
in the line and an input conveyor extension to the input conveyor of the following placement ma-
chine. This intermediate space serves as a buffer to prevent any waiting time during board trans-
port. The input/output conveyor extensions can also be fitted to the beginning and end of a line.
6
CAUTION
Enhanced usability of X-Series S placement machines and accessibility of emergency
STOP button
Always fit an input conveyor extension or an output conveyor extension if the X-Se-
ries S placement machine is in the same line as another X-Series S placement ma-
chine.